 I C Micro-stepping Motor Driver
1.0 General Description
The AMIS-30624 is a single-chip micro-stepping motor driver with a position controller and control/diagnostic interface. It is ready to 2 build intelligent peripheral systems where up to 32 drivers can be connected to one I C master. This significantly reduces system complexity. The chip receives positioning instructions through the bus and subsequently drives the stator coils so the two-phase stepper motor moves to the desired position. The on-chip position controller is configurable (OTP or RAM) for different motor types, positioning ranges and parameters for speed, acceleration and deceleration. Micro-stepping allows silent motor operation and increased positioning resolution. The advanced motion qualification mode enables verification of the complete mechanical system in function of the selected 2 2 motion parameters. The AMIS-30624 can easily be connected to an I C bus where the I C master can fetch specific status information like actual position, error flags, etc. from each individual slave node. An integrated sensorless stall detection stops the motor when running into stall. This enables silent, yet accurate position calibrations during a referencing run and allows semi-closed loop operation when approaching the mechanical end-stops. The chip is implemented in I2T100 technology, enabling both high voltage analog circuitry and digital functionality on the same chip. The AMIS-30624 is fully compatible with the automotive voltage requirements.
2
AMIS-30624
2.0 Product Features
Motor Driver * Micro-stepping technology * Sensorless stall detection * Peak current up to 800mA * Fixed frequency PWM current-control * Selectable PWM frequency * Automatic selection of fast and slow decay mode * No external fly-back diodes required * 14V/24V compliant * Motion qualification mode Controller with RAM and OTP memory * Position controller * Configurable speeds and acceleration * Input to connect optional motion switch I2C interface * Bi-directional 2-wire bus for Inter IC Control * Field programmable node addresses * Full diagnostics and status information Protection * Over-current protection * Under-voltage management * Open circuit detection * High-temp warning and management * Low-temp flag EMI compatibility * High voltage outputs with slope control * HV outputs with slope control
(c)2008 SCILLC. All rights reserved. June 2008 - Rev. 4
Publication Order Number: AMIS30624/D
AMIS-30624
3.0 Applications
The AMIS-30624 is ideally suited for small positioning applications. Target markets include: automotive (headlamp alignment, HVAC, idle control, cruise control), industrial equipment (lighting, fluid control, labeling, process control, XYZ tables, robots) and building automation (HVAC, surveillance, satellite dish, renewable energy systems). Suitable applications typically have multiple axes or require mechatronic solutions with the driver chip mounted directly on the motor.
4.0 Ordering Information
Table 1: Ordering Information Part Number Package AMIS30624C6244G AMIS30624C6244RG AMIS30624C6245G AMIS30624C6245RG SOIC-20 SOIC-20 NQFP-32 (7 x 7 mm) NQFP-32 (7 x 7 mm) Temperature Range -40C.....125C -40C.....125C -40C.....125C -40C.....125C
Shipping Configuration Tube/Tray Tape & Reel Tube/Tray Tape & Reel
Peak Current 800mA 800mA 800mA 800mA
5.0 Quick Reference Data
Table 2: Absolute Maximum Ratings Parameter Vbb Tamb Tst Vesd
(3)
Min. -0.3
(2)
Max. +40
(1)
Unit V C C kV
Supply voltage Ambient temperature under bias Storage temperature Electrostatic discharge voltage on pins
-50 -55 -2
+150 +160 +2
Notes: (1) For limited time <0.5s (2) The circuit functionality is not guaranteed. (3) Human body model (100pF via 1.5 k, according to JEDEC EIA-JESD22-A114-B)
Table 3: Operating Ranges Parameter Vbb Supply voltage Top Operating temperature range Vbb 18V Vbb 29V
Min. +8 -40 -40
Max. +29 +125 +85
Unit V C C
Rev. 4 | Page 2 of 56 | www.onsemi.com
AMIS-30624
6.0 Block Diagram
SDA
SCK
SWI AMIS-30624
I2C-bus Interface
HW
Controller
Position Controller PWM regulator X
I-sense
TST1 TST2
Decoder Main Control Registers OTP - ROM Sinewave Table DAC's
4 MHz
MOTXP MOTXN
Stall detection
Vref
Temp sense
Oscillator PWM regulator Y Charge Pump
I-sense
MOTYP MOTYN
Voltage Regulator
VBB VDD
CPN CPP VCP GND
Figure 1: Block Diagram
PC20060925.1
Rev. 4 | Page 3 of 56 | www.onsemi.com
AMIS-30624
7.0 Pin Out
GND GND GND GND
XN
YP
YP
XN
SDA SCK VDD GND TST1 TST2 GND HW CPN CPP
1 2 3
20 19 18
SWI VBB MOTXP GND MOTXN MOTYP GND MOTYN
32
31
30
29
28
27
26
25
XP XP VBB VBB VBB SWI NC SDA
1 2 3 4 5 6 7 8
24 23 22
YN YN VBB VBB VBB VCP CPP CPN
AMIS-30624
4 5 6 7 8 9 10
17 16 15 14 13 12 11
AMIS-30624
21 20 19 18 17
9
10
11
12
13
14
15
16
VBB
SCK
VDD
GND
TST1
TST2
HW GND
NC
VCP
Top view NQ32
Figure 2: SOIC 20 and NQFP-32 Pin-out
PC20050925.3
PC20060925.2
Table 4: Pin Description Pin Name Pin Description SDA SCK VDD GND TST1 TST2 HW CPN CPP VCP VBB MOTYN MOTYP MOTXN MOTXP SWI NC I C serial data line I C serial clock line Internal supply (needs external decoupling capacitor) Ground, heat sink Test pin (to be tied to ground in normal operation) Test pin (to be left open in normal operation: internally pulled up) Hard wired address bit Negative connection of pump capacitor (charge pump) Positive connection of pump capacitor (charge pump) Charge-pump filter-capacitor Battery voltage supply Negative end of phase Y coil Positive end of phase Y coil Negative end of phase X coil Positive end of phase X coil Switch input Not connected (to be tied to ground)
2 2
SOIC-20 1 2 3 4,7,14,17 5 6 8 9 10 11 12,19 13 15 16 18 20
NQFP-32 8 9 10 11, 14, 25, 26, 31, 32 12 13 15 17 18 19 3, 4, 5, 20, 21, 22 23, 24 27, 28 29, 30 1, 2 6 7, 16
Rev. 4 | Page 4 of 56 | www.onsemi.com
AMIS-30624
8.0 Package Thermal Resistance
8.1 SOIC-20 To lower the junction-to-ambient thermal resistance, it is recommended to connect the ground leads to a printed circuit board (PCB) ground plane layout as illustrated in Figure 3. The junction-to-case thermal resistance is dependent on the copper area, copper 2 thickness, PCB thickness and number of copper layers. Calculating with a total area of 460 mm , 35m copper thickness, 1.6mm PCB thickness and 1 layer, the thermal resistance is 28C/W; leading to a junction-ambient thermal resistance of 63C/W.
Figure 3: PCB Ground Plane Layout Condition
SOIC-20
PC20041128.1
8.2 NQFP-32 The NQFP is designed to provide superior thermal performance, and using an exposed die pad on the bottom surface of the package partly contributes to this. In order to take full advantage of this thermal performance, the PCB must have features to conduct heat away from the package. A thermal grounded pad with thermal vias can achieve this. With a layout as shown in Figure 4, the thermal resistance junction - to - ambient can be brought down to a level of 25C/W.
NQFP-32
PC20041128.2
Figure 4: PCB Ground Plane Layout Condition
Rev. 4 | Page 5 of 56 | www.onsemi.com
AMIS-30624
9.0 DC Parameters
The DC parameters are given for Vbb and temperature in their operating ranges. Currents flowing in the circuit are defined as positive.
Table 5: DC Parameters Symbol Pin(s) Motor Driver IMSmax,Peak IMSmax,RMS IMSabs IMSrel Max. current through motor coil in normal operation Max. RMS current through coil in normal operation Absolute error on coil current Vbb = 12V, Tj = 50 C Vbb = 8V, Tj = 50 C Vbb = 12V, Tj = 150 C Vbb = 8V, Tj = 150 C IMSL Ttw Ttsd
(1) (2) (2)
Parameter
Test Conditions
Min.
Typ. 800 570
Max.
Unit mA mA
RDSon
MOTXP MOTXN Error on current ratio Icoilx / Icoily MOTYP MOTYN On resistance for each motor pin (including bond wire) at IMSmax Pull down current Thermal warning Thermal shutdown Low temperature warning
-10 -7 0.50 0.55 0.70 0.85 2 138 145 Ttw + 10 Ttw - 155 Tamb 125 C Tamb 85 C 6.5 6.5 9.0 Unloaded outputs 7.8 7.1 8V < Vbb < 29V 4.75 3.50 50 8.4 7.5 5 2
10 7 1 1 1 1
% % mA
HiZ mode
Thermal Warning & Shutdown 152 C C C 18 29 10.0 10.0 100 8.9 8.0 5.50 4.5 42 10 2 6 T < 1s Short to Gnd or Vbat - 0.5 0.7 * Vdd 0.1 * Vdd 0.2 * Vdd 30 0.3 * Vdd Vdd + 0.5 29 40V V V V mA A V V V mA V mA k k V V mA V V V
Tlow
Supply and Voltage Regulator Vbb VbbOTP Ibat Ibat_s UV1 UV2 Vdd IddStop VddReset IddLim Rt_OFF Rt_ON Vbb_sw Vmax_sw Ilim_sw I C Serial Interface VIL VIH VnL VnH SDA SCK Input level low
(7) (8)
2
Nominal operating supply range Supply voltage for OTP zapping VBB Total current consumption Sleep mode current consumption Stop voltage high threshold Stop voltage low threshold Internal regulated output VDD
(4) (3)
Digital current consumption Vbb < UV2 Digital supply reset level @ power down
(5)
Current limitation Switch OFF resistance SWI HW
(6)
Pin shorted to ground
Switch Input and Hardwire Address Input Switch ON resistance Vbb range for guaranteed operation of SWI and HW Maximum voltage Current limitation
(6)
Switch to Gnd or Vbat,
Input level high Noise margin at the LOW level for each connected device (including hysteresis) Noise margin at the HIGH level for each connected device (including hysteresis)
Rev. 4 | Page 6 of 56 | www.onsemi.com
AMIS-30624
Table 5: DC Parameters (cont.) Charge Pump Vcp Cbuffer Cpump VCP Output voltage External buffer capacitor CPP CPN External pump capacitor TestBemf I C command 2 Service mode I C command 2 Service mode I C command
2
Vbb > 15V 8V < Vbb < 15V
Vbb+10 2 * Vbb - 5 220 220
Vbb+12.5 2 * Vbb - 2.5
Vbb+15 2 * Vbb 470 470
V V nF nF V k
Motion Qualification Mode Output VOUT Output voltage swing ROUT Output impedance SWI Av Gain = VSWI / VBEMF
Notes: (1) (2) (3) (4) (5) (6) (7) (8)
0 - 4,85 2 0,50
No more than 100 cumulated hours in life time above Ttsd. Thermal shutdown and a low temperature warning are derived from thermal warning. A 10F buffer capacitor of between VBB and GND is the minimum needed. Short connections to the power supply are recommended. Pin VDD must not be used for any external supply The RAM content will not be altered above this voltage. External resistance value seen from pin SWI or HW, including 1k series resistor. If input voltages < - 0.3V, than a resistor between 22 to 100 needs to be put in series If the I2C-bus is operated in Fast Mode VIHmin = 0.7 * Vdd
Rev. 4 | Page 7 of 56 | www.onsemi.com
AMIS-30624
10.0 AC Parameters
The AC parameters are given for Vbb and temperature in their operating ranges. All timing values of the I2C transceiver are referred to VIHman and VILmax levels (see Figure 5).
Table 6: AC Parameters Symbol Pin(s) Power-up Tpu Internal Oscillator fosc I C Transceiver (Generic) CB CI SDA SCK Capacitive load of each bus line 50 100 4.0 4.7 4.0 4.7 0
(2)
2
Parameter Power-up time Frequency of internal oscillator
Test Conditions Guaranteed by design
Min.
Typ.
Max. 10
Unit ms MHz pF pF ns kHz s s s s
3.6
4.0
4.4 400 10
(1)
Capacitance of SDA / SCK pin Pulse width of spikes which must be tSP suppressed by the input filter 2 I C Transceiver (Standard Mode) fSCL tHD,START tLOW tHIGH tSU,START tHD,DATA tSU,DATA tR tF tSU,STOP SDA SCK SCL clock frequency Hold time (repeated) START condition. After this period the first clock pulse is generated. LOW period of the SCK clock HIGH period of the SCK clock Set-up time for a repeated START condition 2 Data hold time for I C bus devices Data set-up time Rise time of SDA and SCK signals Fall time of SDA and SCK signals
3.45 1.0 0.3
(3)
s ns s s s s
250
Set-up time for STOP condition Bus free time between STOP and tBUF START condition 2 I C Transceiver (Fast Mode) fSCL tHD,START tLOW tHIGH tSU,START tHD,DATA tSU,DATA tR tF tSU,STOP tBUF SDA SCK SCL clock frequency Hold time (repeated) START condition. After this period the first clock pulse is generated. LOW period of the SCK clock HIGH period of the SCK clock Set-up time for a repeated START condition 2 Data hold time for I C bus devices Data set-up time Rise time of SDA and SCK signals Fall time of SDA and SCK signals Set-up time for STOP condition Bus free time between STOP and START condition
4.0 4.7 360 0.6 1.3 0.6 0.6 0
(2) (4)
kHz s s s s
0.9
(3)
s ns ns ns s s
100
20 + 0.1CB 20 + 0.1CB 0.6 1.3
300 300
Rev. 4 | Page 8 of 56 | www.onsemi.com
AMIS-30624
Table 6: AC Parameters (cont.) Switch Input and Hardwire Address Input Tsw Tsw_on Motor driver Fpwm Fjit_depth Tbrise Tbfall Tstab Charge Pump fCP
Notes: (1) (2) (3) (4) (5) (6)
SWI HW2
Scan pulse period
(5)
1024 128 PWMfreq = 0 PWMfreq = 1 PWMJen = 1
(6) (6) (6)
s ss 25.0 50,0 kHz kHz % ns ns 35 ms kHz
Scan pulse duration 20.6 41,2
PWM frequency MOTxx
(5)
22.8 45,6 10 170 140
PWM jitter modulation depth Turn-on transient time Turn-off transient time Run current stabilization time
Between 10% and 90% 29
32 250
CPN CPP Charge pump frequency
(5)
The maximum number of connected I2C devices is dependent on the number of available addresses and the maximum bus capacitance to still guarantee the rise and fall times of the bus signals. An I2C device must internally provide a hold time of at least 300ns for the SDA signal (referred to the VIHmin of the SCL signal) to bridge the undefined region of the falling edge of SCL. The maximum tHD,DAT has only to be met if the device does not stretch the LOW period (tLOW) of the SCL signal. A Fast-mode I2C-bus device can be used in a standard-mode I2C bus system, but the requirement tSU,DATA 250ns must than be met. This will automatically be the case if the device does not stretch the LOW period of the SCL signal. If such a device does stretch the LOW period of the SCL signal, it must output the next data bit to the SDA line trmax + tSU,DATA = 1000 + 250 = 1250ns (according to the standard-mode I2C-bus specification) before the SCL line is released. Derived from internal oscillator. See SetMotorParam and PWM regulator.
SDA
START VIHmin VILmax tF tHD,START tR tHD,DATA tSU,DATA
REPEATED START
STOP
START
tBUF tSU,START tSP tSU,STOP
SCK
tLOW
tHIGH
PC20060925.8
Figure 5: I2C Timing Diagrams
Rev. 4 | Page 9 of 56 | www.onsemi.com
AMIS-30624
11.0 Typical Application
VBAT C1
220 nF
100 F
CPN VDD
9 3
220 nF C3
C4
100 nF
C5 VBB
12
C6 VBB
100 nF
CPP
10
VCP
11
19 20
SWI
R2
1 F
C2 SDA 1
18
1 k
MOTXP MOTXN MOTYP MOTYN
Connect to VBAT or GND
I2 C bus
SCK 2
AMIS-30624
16
M
15
Connect to VBAT or GND
R1
HW 8
5 6 4 7 14 17
13
1 k
TST1
TST2
GND
PC20060925.5
Figure 6: Typical Application Diagram
Notes: (1) (2) (3) (4) (5) All resistors are 5%, 1/4 W. Depending on the application, the ESR value and working voltage of C1 must be carefully chosen. C2 must be a ceramic capacitor to assure low ESR. C3 and C4 must be as close as possible to pins CPN, CPP, VCP, and VBB to reduce EMC radiation. C5 and C6 must be close to pins VBB and GND.
12.0 Positioning Parameters
12.1 Stepping Modes One of four possible stepping modes can be programmed: * * * * Half stepping 1/4 micro-stepping 1/8 micro-stepping 1/16 micro-stepping
Rev. 4 | Page 10 of 56 | www.onsemi.com
AMIS-30624
12.2 Maximum Velocity
For each stepping mode, the maximum velocity Vmax can be programmed to 16 possible values given in Table 7.
The accuracy of Vmax is derived from the internal oscillator. Under special circumstances it is possible to change the Vmax parameter while a motion is ongoing. All 16 entries for the Vmax parameter are divided into four groups. When changing Vmax during a motion the application must take care that the new Vmax parameter stays within the same group, otherwise steps might be lost.
Table 7: Maximum Velocity Selection Table Vmax Index Vmax Group (Full-step/s) Hex Dec 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 99 136 167 197 213 228 243 273 303 334 364 395 456 546 729 973 A
Half stepping (Half-step/s) 197 273 334 395 425 456 486 546 607 668 729 790 912 1091 1457 1945
B
C
D
Stepping Mode th th 1/4 1/8 Micro-stepping Micro-stepping (Micro-step/s) (Micro-step/s) 395 790 546 1091 668 1335 790 1579 851 1701 912 1823 973 1945 1091 2182 1213 2426 1335 2670 1457 2914 1579 3159 1823 3647 2182 4364 2914 5829 3891 7782
1/16 Micro-stepping (Micro-step/s) 1579 2182 2670 3159 3403 3647 3891 4364 4852 5341 5829 6317 7294 8728 11658 15564
th
12.3 Minimum Velocity Once the maximum velocity is chosen, 16 possible values can be programmed for the minimum velocity Vmin. Table 8 provides the obtainable values in full-step/s. The accuracy of Vmin is derived from the internal oscillator.
Table 8: Obtainable Values in Full-step/s for the Minimum Velocity Vmin Index Hex 0 1 2 3 4 5 6 7 8 9 A B C D E F
Notes: (1) (2)
Dec 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Vmax Factor 1 1/32 2/32 3/32 4/32 5/32 6/32 7/32 8/32 9/32 10/32 11/32 12/32 13/32 14/32 15/32
Vmax (Full-step/s) A 99 99 3 6 9 12 15 18 21 24 28 31 34 37 40 43 46 B 136 136 4 8 12 16 21 25 30 33 38 42 47 51 55 59 64 167 167 5 10 15 20 26 31 36 41 47 51 57 62 68 72 78 197 197 6 11 18 24 31 36 43 49 55 61 68 73 80 86 93 213 213 6 12 19 26 32 39 46 52 59 66 72 79 86 93 99 228 228 7 13 21 28 35 42 50 56 64 71 78 85 93 99 107 243 243 7 14 22 30 37 45 52 60 68 75 83 91 98 106 113 273 273 8 15 25 32 42 50 59 67 76 84 93 101 111 118 128 303 303 8 17 27 36 46 55 65 74 84 93 103 113 122 132 141 334 334 10 19 31 40 51 61 72 82 93 103 114 124 135 145 156 C 364 364 10 21 32 44 55 67 78 90 101 113 124 135 147 158 170 395 395 11 23 36 48 61 72 86 97 111 122 135 147 160 172 185 456 456 13 27 42 55 71 84 99 113 128 141 156 170 185 198 214 546 546 15 31 50 65 84 99 118 134 153 168 187 202 221 237 256 D 729 729 19 42 65 88 111 134 156 179 202 225 248 271 294 317 340 973 973 27 57 88 118 149 179 210 240 271 301 332 362 393 423 454
The Vmax factor is an approximation. In case of motion without acceleration (AccShape = 1) the length of the steps = 1/Vmin. In case of accelerated motion (AccShape = 0) the length of the first step is shorter than 1/Vmin depending of Vmin, Vmax and Acc.
Rev. 4 | Page 11 of 56 | www.onsemi.com
AMIS-30624
12.4 Acceleration and Deceleration Sixteen possible values can be programmed for Acc (acceleration and deceleration between Vmin and Vmax). Table 9 provides the obtainable values in full-step/s. One observes restrictions for some combination of acceleration index and maximum speed (gray cells). The accuracy of Acc is derived from the internal oscillator.
Table 9: Acceleration and Deceleration Selection Table 99 136 Vmax (FS/s) Acc Index Hex Dec 0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 A 10 B 11 C 12 D 13 E 14 F 15 14785 167 197 213 228 243 273 303 334 364 395 456 546 729 973
Acceleration (Full-step/s) 49 218 1004 3609 6228 8848 11409 13970 16531 19092 21886 24447 27008 29570 34925 40047 106 473 735
29570
The formula to compute the number of equivalent full-step during acceleration phase is:
Nstep =
Vmax 2 - Vmin 2 2 x Acc
12.5 Positioning The position is programmed in the command SetPosition and is given as a number of (micro)steps. According to the chosen stepping mode, the position word must be aligned as described in Table 10. When using command GotoSecurePosition, data is automatically aligned.
Table 10: Position Word Alignment Stepping Mode th 1/16 S B14 th 1/8 S B13 th 1/4 S B12 Half-stepping S B11 PositionShort S S SecurePosition S B9
Notes: (1) (2) LSB: Least significant bit S: Sign bit
B13 B12 B11 B10 S B8
B12 B11 B10 B9 B9 B7
B11 B10 B9 B8 B8 B6
Position Word: Pos[15:0] B10 B9 B8 B7 B6 B5 B9 B8 B7 B6 B5 B4 B8 B7 B6 B5 B4 B3 B7 B6 B5 B4 B3 B2 B7 B6 B5 B4 B3 B2 B5 B4 B3 B2 B1 LSB
B4 B3 B2 B1 B1 0
B3 B2 B1 LSB B2 B1 LSB 0 B1 LSB 0 0 LSB 0 0 0 LSB 0 0 0 0 0 0 0
Shift No shift 1-bit left x2 2-bit left x4 3-bit left x8 No shift No shift
Rev. 4 | Page 12 of 56 | www.onsemi.com
AMIS-30624
12.5.1. Position Ranges A position is coded by using the binary two's complement format. According to the positioning commands used and to the chosen stepping mode, the position range will be as shown in Table 11.
Table 11: Position Range Command SetPosition SetPositionShort Stepping Mode Half stepping th 1/4 micro-stepping th 1/8 micro-stepping th 1/16 micro-stepping Half-stepping Position Range -4096 to +4095 -8192 to +8191 -16384 to +16383 -32768 to +32767 -1024 to +1023 Full Range Excursion 8192 half-steps 16384 micro-steps 32768 micro-steps 65536 micro-steps 2048 half-steps Number of Bits 13 14 15 16 11
When using the command SetPosition, although coded on 16 bits, the position word will have to be shifted to the left by a certain number of bits, according to the stepping mode.
12.5.2. Secure Position A secure position can be programmed. It is coded in 11-bits, thus having a lower resolution than normal positions, as shown in Table 12. See also the command GotoSecurePosition.
Table 12: Secure Position Stepping Mode Half-stepping th 1/4 micro-stepping th 1/8 micro-stepping th 1/16 micro-stepping Secure Position Resolution 4 half-steps th 8 micro-steps (1/4 ) th 16 micro-steps (1/8 ) th 32 micro-steps (1/16 )
Important Notes: (1) The secure position is disabled in case the programmed value is the reserved code "10000000000" (0x400 or most negative position). (2) The resolution of the secure position is limited to 9 bit at start-up. The OTP register is copied in RAM as illustrated below. SecPos1 and SecPos0 = 0.
SecPos10
SecPos9
SecPos8
SecPos2
SecPos1
SecPos0
RAM
SecPos10
SecPos9
SecPos8
SecPos2
OTP
12.5.3. Shaft A shaft bit which can be programmed in OTP or with command SetMotorParam, defines whether a positive motion is a clockwise or counter-clockwise rotation (an outer or an inner motion for linear actuators): * Shaft = 0 MOTXP is used as positive pin of the X coil, while MOTXN is the negative one * Shaft = 1 opposite situation.
Rev. 4 | Page 13 of 56 | www.onsemi.com
AMIS-30624
13.0 Structural Description
See the block diagram in Figure 1. 13.1 Stepper Motor Driver The motor driver receives the control signals from the control logic. The main features are: * Two H-bridges designed to drive a stepper motor with two separated coils. Each coil (X and Y) is driven by one H-bridge and the driver controls the currents flowing through the coils. The rotational position of the rotor, in unloaded condition, is defined by the ratio of current flowing in X and Y. The torque of the stepper motor when unloaded is controlled by the magnitude of the currents in X and Y. * The control block for the H-bridges including the PWM control, the synchronous rectification and the internal current sensing circuitry * The charge pump to allow driving of the H-bridges' high side transistors * Two pre-scale 4-bit DACs to set the maximum magnitude of the current through X and Y * Two DACs to set the correct current ratio through X and Y Battery voltage monitoring is also performed by this block, which provides information to the control logic part. The same applies for the detection and reporting of an electrical problem that could occur on the coils or the charge pump. 13.2 Control Logic (Position Controller and Main Control) The control logic block stores the information provided by the I2C interface (in a RAM or an OTP memory) and digitally controls the positioning of the stepper motor in terms of speed and acceleration, by feeding the right signals to the motor driver state machine. It will take into account the successive positioning commands to properly initiate or stop the stepper motor in order to reach the set point in a minimum time. It also receives feedback from the motor driver part in order to manage possible problems and decide on internal actions and reporting 2 to the I C interface. 13.3 Motion Detection Motion detection is based on the back emf, generated internally in the running motor. When the motor is blocked, for example when it hits the end-position, the velocity and as a result also the generated back emf, is disturbed. The AMIS-30624 senses the back emf, calculates a moving average and compares the value with two independent threshold levels. If the back emf disturbance is bigger than the set threshold, the running motor is stopped. 13.4 Miscellaneous The AMIS-30624 also contains the following: * * * * An internal oscillator needed for the control logic and the PWM control of the motor driver An internal trimmed voltage source for precise referencing A protection block featuring a thermal shutdown and a power-on-reset circuit A 5V regulator (from the battery supply) to supply the internal logic circuitry
Rev. 4 | Page 14 of 56 | www.onsemi.com
AMIS-30624
14.0 Functional Description
This chapter describes the following functional blocks in more detail: * Position controller * Main control and register, OTP memory + ROM * Motor driver The motion detection and I2C control are discussed in separate chapters. 14.1 Position Controller 14.1.1. Positioning and Motion Control A positioning command will produce a motion as illustrated in Figure 7. A motion starts with an acceleration phase from minimum velocity (Vmin) to maximum velocity (Vmax), and ends with a symmetrical deceleration. This is defined by the control logic according to the position required by the application and the parameters programmed by the application during configuration phase. The current in the coils is also programmable.
Acceleration range
Velocity
Deceleration range
Zero speed Hold current
Vmax
Zero speed Hold current
Vmin Position Pstart Pmin P=0
Optional zero switch
Pstop Pmax
Figure 7: Positioning and Motion Control
Table 13: Position Related Parameters Parameter Pmax - Pmin Zero speed hold current Maximum current Acceleration and deceleration Vmin Vmax
Reference See Positioning See Ihold See Irun See Acceleration and deceleration See Minimum velocity See Maximum velocity
Rev. 4 | Page 15 of 56 | www.onsemi.com
AMIS-30624
Different positioning examples are shown in Table 14.
Table 14: Positioning Examples Positioning Examples
Velocity
Short motion
time
Velocity
New positioning command in same direction, shorter or longer, while a motion is running at maximum velocity.
time
Velocity
New positioning command in same direction while in deceleration phase Note: there is no wait time between the deceleration phase and the new acceleration phase.
Velocity
time
New positioning command in reverse direction while motion is running at maximum velocity.
time
Velocity
New positioning command in reverse direction while in deceleration phase.
time
Velocity
New velocity programming while motion is running.
time
Rev. 4 | Page 16 of 56 | www.onsemi.com
AMIS-30624
14.1.2. Dual Positioning A SetDualPosition command allows the user to perform positioning using two different velocities. The first motion is done with the specified Vmin and Vmax velocities in the SetDualPosition command, with the acceleration (deceleration) parameter already in RAM, to a position Pos1[15:0] also specified in SetDualPosition . A second relative motion to a position Pos1[15:0] + Pos2[15:0] is done at the specified Vmin velocity in the SetDualPosition command (no acceleration). Once the second motion is achieved, the ActPos register is reset to zero, whereas TagPos register is not changed.
Pos1[15:0] + Pos2[15:0] Reset ActPos Pos1[15:0] First motion 27 ms
Figure 8: Dual Positioning
Velocity Vmax
Vmin
Second motion t 27 ms
PC20070221.1
Remark: This operation cannot be interrupted or influenced by any further command unless the conditions exist to cause a motor shutdown or by a HardStop command. Sending a SetDualPosition command while a motion is already ongoing is not recommended.
Notes: (0) (1) (2) (3) (4) (5) (6) (7) (8) The priority encoder describes the management of states and commands. All notes below are to be considered illustrative. The last SetPosition command issued during a DualPosition sequence will be kept in memory and executed afterwards. This also applies to the commands SetMotorParam and GotoSecurePosition. Commands such as GetFullStatus1 or GetFullStatus2 will be executed while a Dual Positioning is running. A DualPosition sequence starts by setting TagPos register to SecPos value, provided secure position is enabled otherwise TagPos is reset to zero. The acceleration/deceleration value applied during a DualPosition sequence is the one stored in RAM before the SetDualPosition command is sent. The same applies for Shaft bit, but not for Irun, Ihold and StepMode, which can be changed during the Dual Positioning sequence. The Pos1, Pos2, Vmax and Vmin values programmed in a SetDualPosition command apply only for this sequence. All further positioning will use the parameters stored in RAM (programmed for instance by a former SetMotorParam command). Commands ResetPosition, SetDualPosition, and SoftStop will be ignored while a DualPosition sequence is ongoing, and will not be executed afterwards. A SetMotorParam command should not be sent during a SetDualPosition sequence. If for some reason ActPos equals Pos1[15:0] at the moment the SetDualPosition command is issued, the circuit will enter in deadlock state. Therefore, the application should check the actual position by a GetFullStatus2 command prior to send the SetDualPosition command.
Rev. 4 | Page 17 of 56 | www.onsemi.com
AMIS-30624
14.1.3. Position Periodicity Depending on the stepping mode the position can range from -4096 to +4095 in half-step to -32768 to +32767 in 1/16th micro-stepping mode. One can project all these positions lying on a circle. When executing the command SetPosition, the position controller will set the movement direction in such a way that the traveled distance is at a minimum. Figure 9 illustrates that the moving direction going from ActPos = +30000 to TagPos = -30000 is clockwise. If a counter clockwise motion is required in this example, several consecutive SetPosition commands can be used. For larger movements, one could also use the command RunVelocity.
+10000
+20000 ActPos = +30000
0
Motion direction TagPos = -30000
-10000
-20000
Figure 9: Motion Direction is Function on Difference Between ActPos and TagPos
14.1.4. Hardwired Address HW In Figure 10 a simplified schematic diagram is shown of the HW comparator circuit. The HW pin is sensed via two switches STOP and SBOT. The DriveHS and DriveLS control lines are alternatively closing STOP and SBOT , connecting HW pin with a current to resistor converter. Closing STOP (DriveHS = 1) will sense a current to GND. In that case the top I R converter output is low, via the closed passing switch SPASS_T this signal is fed to the "R" comparator which output HW_Cmp is high. Closing bottom switch SBOT (DriveLS = 1) will sense a current to VBAT. The corresponding I R converter output is low and via SPASS_B fed to the comparator. The output HW_Cmp will be high.
SPASS_T
I R
State
HW
STOP SBOT
DriveHS LOGIC DriveLS
"R"-Comp
I R 64 ms Debouncer
High Low Float
1 = R2GND
2 = R2VBAT
3 = OPEN
SPASS_B Rth
COMP
32 s Debouncer
HW_Cmp
PC20060926.1
Figure 10: Simplified Schematic Diagram of the HW Comparator
Rev. 4 | Page 18 of 56 | www.onsemi.com
AMIS-30624
Three cases can be distinguished (see also Figure 10): HW is connected to ground: R2GND or Drawing 1 HW is connected to VBAT: R2VBAT or Drawing 2 HW is floating: OPEN or Drawing 3
Table 15: State Diagram of the HW Comparator Previous State DriveLS DriveHS HW_Cmp Float 1 0 0 Float 1 0 1 Float 0 1 0 Float 0 1 1 Low 1 0 0 Low 1 0 1 Low 0 1 0 Low 0 1 1 High 1 0 0 High 1 0 1 High 0 1 0 High 0 1 1 New State Float High Float Low Low High Float Low Float High High Low Condition R2GND or OPEN R2VBAT R2VBAT or OPEN R2GND R2GND or OPEN R2VBAT R2VBAT or OPEN R2GND R2GND or OPEN R2VBAT R2VBAT or OPEN R2GND Drawing 1 or 3 2 2 or 3 1 1 or 3 2 2 or 3 1 1 or 3 2 2 or 3 1
The logic is controlling the correct sequence in closing the switches and in interpreting the 32s de-bounced HW_Cmp output accordingly. The output of this small state-machine is corresponding to: High or address = 1 Low or address = 0 Floating As illustrated in Table 15, the state is depending on the previous state, the condition of the two switch controls (DriveLS and DriveHS) and the output of HW_Cmp. Figure 11 shows an example of a practical case where a connection to VBAT is interrupted.
Condition R2VBAT DriveHS
Tsw = 1024 s
OPEN
R2VBAT
R2GND
t
t DriveLS
Tsw_on = 128 s
t "R"-Comp Rth t HW_Cmp t State Float Float Float Float High High High High High High High High Low Low Low t
PC20060926.2
Figure 11: Timing Diagram Showing the Change in States for HW Comparator
Rev. 4 | Page 19 of 56 | www.onsemi.com
AMIS-30624
R2VBAT A resistor is connected between VBAT and HW. Every 1024s SBOT is closed for a period of 128s and a current is sensed. The output of the I R converter is low and the HW_Cmp output is high. Assuming the previous state was floating, the internal LOGIC will interpret this as a change of state and the new state will be High (see also Table 15). The next time SBOT is closed the same condition is observed. The previous state was high, so based on Table 15 the new state remains unchanged. This high state will be interpreted as HW address = 1. OPEN In case the HW connection is lost (broken wire, bad contact in connector) the next time SBOT is closed this will be sensed. There will be no current, the output of the corresponding I R converter is high and the HW_Cmp will be low. The previous state was High. Based on Table 15 one can see that the state changes to float. This will trigger a motion to secure position after a debounce time of 64 ms. This prevents false triggering in case of micro interruptions of the power supply. See also Electrical Transient Conduction Along Supply Lines. R2GND If a resistor is connected between HW and the GND, a current is sensed every 1024s when STOP is closed. The output of the top I R converter is low and as a result the HW_Cmp output switches to high. Again based on the stated diagram in Table 15 one can see that the state will change to low. This low state will be interpreted as HW address = 0. 14.1.5. External Switch SWI As illustrated in Figure 12, the SWI comparator is almost identical to HW. The major difference is in the limited number of states. Only open or closed is recognised leading to respectively ESW = 0 and ESW = 1.
SPASS_T
I R
State SWI STOP SBOT DriveHS LOGIC DriveLS
"R"-Comp
I R
Closed
Open
1 = R2GND
2 = R2VBAT
3 = OPEN
SPASS_B Rth
COMP
32 s Debouncer
SWI_Cmp
PC20060926.3
Figure 12: Simplified Schematic Diagram of the SWI Comparator
As illustrated in Figure 14, a change in state is always synchronized with DriveHS or DriveLS. The same synchronization is valid for updating the internal position register. This means that after every current pulse (or closing of STOP or SBOT) the state of position switch together with the corresponding position is memorized. Using the GetActualPos commands reads back the ActPos register and the status of ESW. In this way the master node may get synchronous information about the state of the switch together with the position of the motor. See Figure 13.
Rev. 4 | Page 20 of 56 | www.onsemi.com
AMIS-30624
Byte Content Bit 7 GetFullStatus1 Response Frame Structure Bit 6 Bit 5 Bit 4 Bit 3
Bit 2
Bit 1
Bit 0
0 1 2 3 4 5 6 7 8
Address Address Data 1 Data 2 Data 3 Data 4 Data 5 Data 6 Data 7
1 OTP3 1 1 Irun[3:0] Vmax[3:0] AccShape StepMode[1:0] VddReset StepLoss ElDef Motion[2:0] 1 1 1 AbsThr[3:0]
1 1
OTP2 OTP3
OTP1 OTP2
Shaft UV2 ESW 1
TSD OVC1 1
OTP0 HW 1 OTP1 OTP0 HW Ihold[3:0] Vmin[3:0] Acc[3:0] TW Tinfo[1:0] OVC2 Stall CPFail 1 1 1 DelThr[3:0]
Figure 13: GetFullStatus1 I2C Commando
Important remark: Every 512s this information is refreshed.
Tsw =1024 s 512 s
DriveHS
DriveLS
Tsw_on = 128 s
t
t "R"-Comp Rth t
SWI_Cmp
120 s
t ESW 0
ActPos + 1
1
ActPos + 2
1
ActPos + 3
1 t
ActPos
ActPos
PC20060926.4
t
Figure 14: Timing Diagram Showing the Change in States for SWI Comparator
Rev. 4 | Page 21 of 56 | www.onsemi.com
AMIS-30624
14.2 Main Control and Register, OTP Memory + ROM 14.2.1. Power-up Phase The power-up phase of the AMIS-30624 will not exceed 10ms. After this phase, the AMIS-30624 is in shutdown mode, ready to receive 2 I C messages and execute the associated commands. After power-up, the registers and flags are in the reset state; some of them being loaded with the OTP memory content (see Table 18). 14.2.2. Reset State After power-up, or after a reset occurrence (e.g. a micro cut on pin VBB has made Vdd go below VddReset level), the H-bridges will be in high impedance mode, and the registers and flags will be in a predetermined position. This is documented in Table 18 and Table 19. 14.2.3. Soft Stop A soft stop is an immediate interruption of a motion, but with a deceleration phase. At the end of this action, the register TagPos is loaded with the value contained in register ActPos to avoid an attempt of the circuit to achieve the motion (seeTable 18). The circuit is then ready to execute a new positioning command, provided thermal and electrical conditions allow for it. 14.2.4. Thermal Shutdown Mode When thermal shutdown occurs, the circuit performs a SoftStop command and goes to motor shutdown mode (see Figure 15). 14.2.5. Temperature Management The AMIS-30624 monitors temperature by means of two thresholds and one shutdown level, as illustrated in the Figure 15. The only condition necessary to reset flags and (respectively thermal warning and thermal shutdown) is when the temperature is lower than Ttw causing the occurrence of a GetFullStatus1 I2C frame.
= '01' = '0' = '0'
PC20070219.1
T < Tlow
LOW TEMP
T > Tlow
= '01' = '0' = '0'
NORMAL TEMP
T > T tw
T < T tw & I2C frame

= '01' = '0' = '0'
T < T tw & I2C frame

T < T tw
THERMAL WARNING
= '01' = '0' = '0'
POST THERMAL SHUTDOWN 2
= '01' = '0' = '0'
POST THERMAL WARNING
T > Ttw T > T tsd
T > Ttw
T < Ttw
T > T tsd
= '01' = '0' = '0'
POST THERMAL SHUTDOWN 1
T < T tsd
THERMAL SHUTDOWN
Tinfo> = '01' TW> = '0' TSD> = '0'
Figure 15: State Diagram Temperature Management
Rev. 4 | Page 22 of 56 | www.onsemi.com
AMIS-30624
14.2.6. Battery Under-voltage Management The AMIS-30624 monitors the battery voltage by means of one threshold and one shutdown level, as illustrated in Figure 16. The only condition necessary to reset flags and is to recover a battery voltage higher than UV1 and to receive a GetFullStatus1 command.
- = '0' - = '0'
NORMAL VOLTAGE
Vbb > UV1 & I2C frame Vbb < UV2 No Motion Vbb > UV1 & I2C frame Vbb < UV2 & Motion Ongoing
- = '1' - = '0' - Motor Shutdown
STOP MODE 2
- = '1' - = '1' - HardStop - Motor Shutdown
STOP MODE 1
PC20060926.5
Figure 16: State Diagram Battery Voltage Management
14.2.7. OTP Register 14.2.7.1 OTP Memory Structure Table 16 shows where the parameters to be stored in the OTP memory are located.
Table 16: OTP Memory Structure Address Bit 7 0x00 OSC3 0x01 0x02 AbsThr3 0x03 Irun3 0x04 Vmax3 0x05 SecPos10 0x06 SecPos7 0x07 DelThr3 Bit 6 OSC2 TSD2 AbsThr2 Irun2 Vmax2 SecPos9 SecPos6 DelThr2 Bit 5 OSC1 TSD1 AbsThr1 Irun1 Vmax1 SecPos8 SecPos5 DelThr1 Bit 4 OSC0 TSD0 AbsThr0 Irun0 Vmax0 Shaft SecPos4 DelThr0 Bit 3 IREF3 BG3 PA3 Ihold3 Vmin3 Acc3 SecPos3 StepMode1 Bit 2 IREF2 BG2 PA2 Ihold2 Vmin2 Acc2 SecPos2 StepMode0 Bit 1 IREF1 BG1 PA1 Ihold1 Vmin1 Acc1 LOCKBT Bit 0 IREF0 BG0 PA0 Ihold0 Vmin0 Acc0 LOCKBG
Parameters stored at address 0x00 and 0x01 and bit LOCKBT are already programmed in the OTP memory at circuit delivery. They correspond to the calibration of the circuit and are just documented here as an indication. Each OPT bit is at `0' when not zapped. Zapping a bit will set it to `1'. Thus only bits having to be at `1' must be zapped. Zapping of a bit already at `1' is disabled. Each OTP byte will be programmed separately (see command SetOTPparam). Once OTP programming is completed, bit LOCKBG can be zapped, to disable future zapping, otherwise any OTP bit at `0' could still be zapped by using a SetOTPparam command.
Table 17: OTP Overwrite Protection Lock Bit LOCKBT (factory zapped before delivery) LOCKBG
Protected Bytes 0x00 to 0x01 0x00 to 0x07
Note: Zapped bits will really be "active" after a GetOTPparam or a ResetToDefault command or after a power-up.
Rev. 4 | Page 23 of 56 | www.onsemi.com
AMIS-30624
The command used to load the application parameters via the I2C bus in the RAM prior to an OTP memory programming is SetMotorParam. This allows for a functional verification before using a SetOTPparam command to program and zap separately one OTP memory byte. A GetOTPparam command issued after each SetOTPparam command allows verification of the correct byte zapping. 14.2.7.2 Application Parameters Stored in OTP Memory Except for the physical address PA[3:0], these parameters, although programmed in a non-volatile memory, can still be overridden in 2 RAM by an I C writing operation. PA[3:0] In combination with hired wired (HW) address, it forms the physical address AD[6:0] of the stepper-motor. Up to 32 stepper motors can theoretically be connected to the same I2C bus. Absolute threshold used for the motion detection
Index 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 AbsThr 00 00 01 01 10 10 11 11 00 00 01 01 10 10 11 11 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 AbsThr level (V) Disable 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5
AbsThr[3:0]
DelThr[3:0]
Delta threshold used for the motion detection
Index 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 DelThr 00 00 01 01 10 10 11 11 00 00 01 01 10 10 11 11 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 DelThr level (V) Disable 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75
Rev. 4 | Page 24 of 56 | www.onsemi.com
AMIS-30624
Irun[3:0] Current amplitude value to be fed to each coil of the stepper motor. The table below provides the 16 possible values for IRUN.
Index 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 Irun 00 00 01 01 10 10 11 11 00 00 01 01 10 10 11 11 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 Run Current (mA) 59 71 84 100 119 141 168 200 238 283 336 400 476 566 673 800
Ihold[3:0]
Hold current for each coil of the stepper motor. The table below provides the 16 possible values for IHOLD.
Index 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 Ihold 00 00 01 01 10 10 11 11 00 00 01 01 10 10 11 11 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 Hold Current (mA) 59 71 84 100 119 141 168 200 238 283 336 400 476 566 673 0
StepMode
Indicator of stepping mode to be used.
StepMode 0 0 0 1 1 0 1 1 Step Mode 1/2 stepping 1/4 stepping 1/8 stepping 1/16 stepping
Shaft
Indicator of reference position. If Shaft = `0', the reference position is the maximum inner position, whereas if Shaft = `1', the reference position is the maximum outer position.
SecPos[10:0] Secure position of the stepper motor. This is the position to which the motor is driven in case HW connection is lost. If SecPos[10:0] = "100 0000 0000", this means that secure position is disabled, e.g. the stepper motor will be kept in the position occupied at the moment these events occur. * The secure position is coded on 11 bits only, providing actually the most significant bits of the position, the non coded least significant bits being set to `0'. See also Table 10.
Rev. 4 | Page 25 of 56 | www.onsemi.com
AMIS-30624
Vmax[3:0] Maximum velocity
Index 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 Vmax 00 00 01 01 10 10 11 11 00 00 01 01 10 10 11 11 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 Vmax (full step/s) 99 136 167 197 213 228 243 273 303 334 364 395 456 546 729 973 Group A
B
C
D
Vmin[3:0]
Minimum velocity
Index 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 Vmin 00 00 01 01 10 10 11 11 00 00 01 01 10 10 11 11 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 Vmax factor 1 1/32 2/32 3/32 4/32 5/32 6/32 7/32 8/32 9/32 10/32 11/32 12/32 13/32 14/32 15/32
Acc[3:0]
Acceleration and deceleration between Vmax and Vmin.
Index 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 Acc 00 00 01 01 10 10 11 11 00 00 01 01 10 10 11 11 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 Acceleration (full step/s) 49 (*) 218 (*) 1004 . 3609 . 6228 . 8848 . 11409 . 13970 . 16531 . 19092 (*) 21886 (*) 24447 (*) 27008 (*) 29570 (*) 34925 (*) 40047 (*)
(*) restriction on speed
*
Rev. 4 | Page 26 of 56 | www.onsemi.com
AMIS-30624
14.2.8. RAM Registers
Table 18: RAM Registers Register Actual position Last programmed position Acceleration shape Coil peak current Coil hold current Minimum velocity Maximum velocity Shaft Acceleration/ deceleration Secure position Stepping mode Stall detection absolute threshold Stall detection delta threshold Stall detection delay Stall detection sampling PWM jitter 100% duty cycle stall disable PWM frequency Mnemonic ActPos Pos/ TagPos AccShape Irun Ihold Vmin Vmax Shaft Acc SecPos StepMode AbsThr DelThr FS2StallEn MinSamples PWMJEn DC100SDis PWMFreq Length (Bit) 16 16 1 4 4 4 4 1 4 11 2 4 4 3 3 1 1 1 Related Commands GetFullStatus2 GotoSecurePos ResetPosition GetFullStatus2 GotoSecurePos ResetPosition SetPosition GetFullStatus11 ResetToDefault SetMotorParam GetFullStatus11 ResetToDefault SetMotorParam GetFullStatus1 1 ResetToDefault SetMotorParam GetFullStatus11 ResetToDefault SetMotorParam GetFullStatus11 ResetToDefault SetMotorParam GetFullStatus1 1 ResetToDefault SetMotorParam GetFullStatus11 ResetToDefault SetMotorParam GetFullStatus21 ResetToDefault SetMotorParam GetFullStatus1 SetStallParam GetFullStatus1 SetStallParam GetFullStatus1 SetStallParam GetFullStatus2 SetStallParam GetFullStatus2 SetStallParam GetFullStatus2 SetStallParam GetFullStatus2 SetStallParam SetMotorParam Comment 16-bit signed 16-bit signed (see Positioning) `0' normal acceleration from Vmin to Vmax `1' motion at Vmin without acceleration Operating current See look-up table Irun Standstill current See look-up table Ihold See Section 13.3 Minimum Velocity See look-up table Vmin See Section 13.2 Maximum Velocity See look-up table Vmax Direction of movement for positive velocity See Section 13.4 Acceleration See look-up table Acc Target position when LIN connection fails; 11 MSBs of 16-bit position (LSBs fixed to `0') See Section 13.1 Stepping Modes See look-up table StepMode See Section 15.4 Motion detection See Section 15.4 Motion detection See Section 15.4 Motion detection See Section 15.4 Motion detection `1' means jitter is added `1' means stall detection is disabled in case PWM regulator runs at = 100% `1' means 44 kHz is selected `000' `000' `0' `0' `0' From OTP memory Note 1 Reset State
`0'
Note: A ResetToDefault command will act as a reset of the RAM content, except for ActPos and TagPos, which are registers that are not modified. Therefore, the application should not send a ResetToDefault during a motion, to avoid any unwanted change of parameter.
Rev. 4 | Page 27 of 56 | www.onsemi.com
AMIS-30624
14.2.9. Flags Table
Table 19: Flags Table Flag Charge pump failure Electrical defect External switch status Mnemonic CPFail Length (Bit) 1 1 1 Related Commands GetFullStatus1 Comment `0' = charge pump OK `1' = charge pump failure reset only after GetFullStatus or or or or resets only after GetFullStatus1 `0' = open `1' = close "x00" = Stop "001" = inner motion acceleration "010" = inner motion deceleration "011" = inner motion max. speed "101" = outer motion acceleration "110" = outer motion deceleration "111" = outer motion max. speed `1' = over current reset only after GetFullStatus1 `1' = over current reset only after GetFullStatus1 `0' if SecPos = "100 0000 0000" `1' otherwise `1' = step loss due to under voltage, over current or open circuit `1' = Vbemf > Average + DeltaThr `1' = Vbemf < Average - DeltaThr `1' = Vbemf > AbsThr Stall detected "00" = normal temperature range "01" = low temperature warning "10" = high temperature warning "11" = motor shutdown `1' = shutdown (> 155C typ.) reset only after GetFullStatus1 and if = "00" `1' = over temp (> 145C) reset only after GetFullStatus1 and if = "00" `0' = Vbb > UV2 `1' = Vbb UV2 reset only after GetFullStatus1 Set at `1' after power-up of the circuit. If this was due to a supply micro-cut, it warns that the RAM contents may have been lost; can be reset to `0' with a GetFullStatus1 command. Reset State `0' `0' `0'
ElDef ESW
GetFullStatus1 GetFullStatus1
Motion status
Motion
3
GetFullStatus1
"000"
Over current in coil X Over current in coil Y Secure position enabled Step loss Delta high stall Delta low stall Absolute stall Stall Temperature info
OVC1 OVC2 SecEn StepLoss DelStallHi DelStallLo AbsStall Stall Tinfo
1 1 1 1 1 1 1 1 2
GetFullStatus1 GetFullStatus1 Internal use GetFullStatus1 GetFullStatus2 GetFullStatus2 GetFullStatus2 GetFullStatus1 GetFullStatus1
`0' `0' NA `1' `0' `0' `0' `0' "00"
Thermal shutdown Thermal warning Battery stop voltage
TSD
1 1 1
GetFullStatus1
`0' `0' `0'
TW
GetFullStatus1
UV2
GetFullStatus1
Digital supply reset
VddReset
1
GetFullStatus1
`1'
Rev. 4 | Page 28 of 56 | www.onsemi.com
AMIS-30624
14.2.10. Priority Encoder The table below describes the state management performed by the main control block.
Table 20: Priority Encoder State Command GetOTPparam Stopped Motor Stopped, Ihold in Coils OTP refresh; 2 I C slave response I C slave response I C slave response OTP refresh; OTP to RAM; AccShape reset RAM update RAM update TagPos and ActPos reset TagPos updated; TagPos updated GotoPos
Continuous motion;
2 2
GotoPos Motor Motion Ongoing OTP refresh; 2 I C slave response I C slave response I C slave response OTP refresh; OTP to RAM; AccShape reset RAM update (note 5) RAM update
2 2
DualPosition No Influence on RAM and TagPos OTP refresh; 2 I C slave response I C slave response I C slave response OTP refresh; OTP to RAM; AccShape reset (note 2) RAM update RAM update
2 2
SoftStop Motor Decelerating OTP refresh; 2 I C slave response I C slave response I C slave response OTP refresh; OTP to RAM; AccShape reset RAM update RAM update
2 2
HardStop
ShutDown
Motor Forced to Motor Stopped, Stop H-bridges in Hi-Z OTP refresh; 2 I C slave response I C slave response I C slave response OTP refresh; OTP to RAM; AccShape reset RAM update RAM update
2 2
OTP refresh; 2 I C slave response I C slave response; if ( or = `0' then Stopped I C slave response OTP refresh; OTP to RAM; AccShape reset RAM update RAM update TagPos and ActPos reset
2 2
GetFullStatus1 [attempt to clear all flags] (note 1)
GetFullStatus2 ResetToDefault [ ActPos and TagPos are not altered ] SetMotorParam [ Master takes care about proper update ] SetStallParam ResetPosition SetPosition RunVelocity
TagPos updated
GotoPos If = `1' then TagPos = SecPos; GotoPos DualPosition HardStop; HardStop; HardStop; = `1' = `1' = `1' SoftStop Shutdown HardStop HardStop HardStop If = `1' then TagPos = SecPos If = `1' then TagPos = SecPos
GotoSecPosition
DualPosition HardStop SoftStop HardStop [ ( or or ) = `1' = `1' ] Thermal shutdown [ = `1' ] Motion finished
Shutdown NA
SoftStop Stopped
SoftStop Stopped Stopped; Stopped; TagPos =ActPos TagPos =ActPos NA
With the following color code: Command ignored Transition to another state Master is responsible for proper update (see Note 5)
Rev. 4 | Page 29 of 56 | www.onsemi.com
AMIS-30624
Notes:
1) 2) 3)
= or or or After power-on-reset, the Shutdown state is entered. The shutdown state can only be left after GetFullStatus1 command (so that the master could read the flag). A DualPosition sequence runs with a separate set of RAM registers. The parameters that are not specified in a DualPosition command are loaded with the values stored in RAM at the moment the DualPosition sequence starts. AccShape is forced to `1' during second motion even if a ResetToDefault command is issued during a DualPosition sequence, in which case AccShape at `0' will be taken into account after the DualPosition sequence. A GetFullStatus1 command will return the default parameters for Vmax and Vmin stored in RAM. Shutdown state can be left only when and flags are reset. Flags can be reset only after the master could read them via a GetFullStatus1 command, and provided the physical conditions allow for it (normal temperature, correct battery voltage and no electrical or charge pump defect). A SetMotorParam command sent while a motion is ongoing (state GotoPos) should not attempt to modify Acc and Vmin values. This can be done during a DualPosition sequence since this motion uses its own parameters, the new parameters will be taken into account at the next SetPosition command. = `1' when register SecPos is loaded with a value different from the most negative value (i.e. different from 0x400 = "100 0000 0000") flag allows user to distinguish whether state stopped was entered after HardStop/SoftStop or not. is set to `1' when leaving state HardStop or SoftStop and is reset during first clock edge occurring in state Stopped. While in state stopped, if ActPos TagPos there is a transition to state GotoPos. This transition has the lowest priority, meaning that , , etc. are first evaluated for possible transitions.
4) 5) 6)
7) 8) 9)
10) If is active, then SetPosition and GotoSecurePosition commands are ignored (they will not modify TagPos register whatever the state). Other command like DualPosition or ResetPosition will be executed if allowed by current state. can only be cleared by a GetFullStatus1 command.
Thermal shutdown
POWER ON
DUALPOSITION
SOFTSTOP
HardStop
HardStop
DualPosition
Motion Finished
HARDSTOP
Thermal Shutdown SoftStop
Motion Finished GetFullStatus1 GotoSecPos
HardStop
SHUTDOWN
Thermal shutdown HardStop
STOPPED
SetPos
GOTOPOS
Motion Finished
Priorities 1 2 3 Motion Finished
PC20070323.1
Figure 17: State Diagram
Rev. 4 | Page 30 of 56 | www.onsemi.com
AMIS-30624
14.3 Motor Driver 14.3.1. Current Waveforms in the Coils Figure 18 illustrates the current fed to the motor coils by the motor driver in half step mode.
Ix Iy
Coil X
t
Coil Y
PC20051205.1
Figure 18: Current Waveforms in Motorcoils X and Y in Halfstep Mode
Whereas Figure 19 below shows the current fed to one coil in 1/16th micro stepping (one electrical period).
Ix Iy
Coil X
t
Coil Y
PC20051123.4
Figure 19: Current Waveforms in Motorcoils X and Y in 1/16 Microstep mode
th
14.3.2. PWM Regulation In order to force a given current (determined by Irun or Ihold and the current position of the rotor) through the motor coil while ensuring high energy transfer efficiency, a regulation based on PWM principle is used. The regulation loop performs a comparison of the sensed output current to an internal reference, and features a digital regulation generating the PWM signal that drives the output switches. The
Rev. 4 | Page 31 of 56 | www.onsemi.com
AMIS-30624
zoom over one micro-step in Figure 19 shows how the PWM circuit performs this regulation. To reduce the current ripple, a higher PWM frequency should be selectable. The RAM register PWMfreq is used for this (Bit 6 in Data 7 of SetMotorParam).
Table 21: PWM Frequency Selection PWMfreq 0 1 Applied PWM Frequency 22.8 kHz 45.6 kHz
14.3.3. PWM Jitter To lower the power spectrum for the fundamental and higher harmonics of the PWM frequency, jitter can be added to the PWM clock. The RAM register PWMJEn is used for this. (Bit 0 in Data 7 of SetMotorParam or SetStallParam). Readout with GetFullStatus1.
Table 22: PWM Jitter Selection PWMJEn 0 1 Status Single PWM frequency Added jitter to PWM frequency
14.3.4. Motor Starting Phase At motion start, the currents in the coils are directly switched from Ihold to Irun with a new sine/cosine ratio corresponding to the first half (or micro) step of the motion.
14.3.5. Motor Stopping Phase At the end of the deceleration phase, the currents are maintained in the coils at their actual DC level (hence keeping the sine/cosine ratio between coils) during the stabilization time tstab (see Table 6). The currents are then set to the hold values, respectively, Ihold x sin(TagPos) and Ihold x cos(TagPos) as illustrated below. A new positioning order can then be executed.
Figure 20: Motor Stopping Phase
14.3.6. Charge Pump Monitoring If the charge pump voltage is not sufficient for driving the high side transistors (due to a failure), an internal HardStop command is issued. This is acknowledged to the master by raising the flag (available with command GetFullStatus1). In case this failure occurs while a motion is ongoing, the flag is also raised.
Rev. 4 | Page 32 of 56 | www.onsemi.com
AMIS-30624
14.3.7. Electrical Defect on Coils, Detection and Confirmation The principle relies on the detection of a voltage drop on at least one transistor of the H-bridge. Then the decision is taken to open the transistors of the defective bridge. This allows the detection of the following short circuits: * External coil short circuit * Short between one terminal of the coil and Vbat or Gnd Open circuits are detected by a 100 percent PWM duty cycle value during a long time.
Table 23: Electrical Defect Detection Pins Yi or Xi Yi or Xi Yi or Xi Y1 and Y2 X1 and X2 Xi and Yi Fault Mode Short circuit to GND Short circuit to Vbat Open Short circuited Short circuited Short circuited
Remark: One cannot detect an internal short in the motor.
14.3.8. Motor Shutdown Mode A motor shutdown occurs when: * The chip temperature rises above the thermal shutdown threshold Ttsd (see Thermal Shutdown Mode) * The battery voltage goes below UV2 (see Battery Voltage Management) * Flag = `1', meaning an electrical problem is detected on one or both coils, e.g. a short circuit * Flag = `1', meaning there is a charge pump failure A motor shutdown leads to the following: * H-bridges in high impedance mode * The TagPos register is loaded with the ActPos (to avoid any motion after leaving the motor shutdown mode) The I2C interface remains active, being able to receive orders or send status. The conditions to get out of a motor shutdown mode are: * Reception of a GetFullStatus1 command AND * The four causes above are no longer detected This leads to H-bridges in Ihold mode, hence the circuit is ready to execute any positioning command. This can be illustrated in the following sequence given as an application tip. The master can check whether there is a problem or not and decide which application strategy to adopt.
Rev. 4 | Page 33 of 56 | www.onsemi.com
AMIS-30624
Tj Tsd or Vbb UV2 or = `1' or = `1'
SetPosition frame
GetFullStatus1 frame
GetFullStatus1 frame
- The circuit is driven in motor shutdown mode - The application is not aware of this
- The position set-point is updated by the 2 I C Master - Motor shutdown mode no motion - The application is still unaware
...
- The application is - Possible confirmation aware of a problem of the problem - Reset or or or or or by the application - Possible new detection of over temperature or low voltage or electrical problem Circuit sets or or or or or again at `1'
Figure 21: Example of Possible Sequence Used to Detect and Determine Cause of Motor Shutdown
Important: While in shutdown mode, since there is no hold current in the coils, the mechanical load can cause a step loss, which cannot be flagged by the AMIS-30624. Warning: The application should limit the number of consecutive GetFullStatus1 commands to try to get the AMIS-30624 out of shutdown mode. When this proves to be unsuccessful, for example if there is a permanent defect, the reliability of the circuit could be altered since GetFullStatus1 attempts to disable the protection of the H-bridges.
14.4 Motion Detection Motion detection is based on the back emf generated internally in the running motor. When the motor is blocked, for example when it hits the end-position, the velocity and as a result also the generated back emf, is disturbed. The AMIS-30624 senses the back emf, calculates a moving average and compares the value with two independent threshold levels: Absolute threshold (AbsThr[3:0] ) and Delta threshold (DelThr[3:0] ). Instructions for the correct use of these two levels in combination with three additional parameters (MinSamples, FS2StallEn and DC100SDis) are outside the scope of this datasheet. Detailed information is available in a dedicated white paper "Robust Motion Control with AMIS-3062x Stepper Motor Drivers", available on http://www.amis.com/. If the motor is accelerated by a pulling or propelling force and the resulting back emf increases above the Delta threshold (+ THR), then is set. When the motor is slowing down and the resulting back emf decreases below the Delta threshold (- THR), then is set. When the motor is blocked and the velocity is zero after the acceleration phase, the back emf is low or zero. When this value is below the Absolute threshold, is set. The flag is the OR function of OR OR .
Rev. 4 | Page 34 of 56 | www.onsemi.com
AMIS-30624
Velocity Vbemf + THR Vmax Motor speed Vmin Vbemf t - THR t
Vbemf
Vbemf
DeltaStallHi VABSTH Back emf t AbsStall DeltaStallLo t
t
t
Figure 22: Triggering of the Stall Flags in Function of Measured Back emf and the Set Threshold Levels Table 24: Truth Table Condition Vbemf < Average - DelThr Vbemf > Average + DelThr Vbemf < AbsThr
1 0 0
0 1 0
0 0 1
1 1 1
The motion will only be detected when the motor is running at the maximum velocity, not during acceleration or deceleration. If during positioning a mechanical obstacle is detected (stall), an (internal) hardstop is generated. The motor will stop immediately and as a consequence the and flags are set. The position in the internal counter will be copied to the ActPos register. All flags can be read out with the GetFullStatus1. If Stall appears during DualPosition then the first phase is cancelled (via internal Hardstop) and after timeout (26.6ms) the second phase at Vmin starts. Important Remark: Using GetFullStatus1 will read AND clear the following flags: , , , , and . New positioning is possible and the ActPos register will be further updated. Motion detection is disabled when the RAM registers AbsThr[3:0] and DelThr[3:0] are empty or zero. Both levels can be programmed using the I2C command SetStallParam in the registers AbsThr[3:0] and DelThr[3:0]. Also in the OTP register AbsThr[3:0] and 2 DelThr[3:0] can be set using the I C command SetOTPParam. These values are copied in the RAM registers during power on reset.
Rev. 4 | Page 35 of 56 | www.onsemi.com
AMIS-30624
Value Table:
Table 25: Absolute Threshold Settings AbsThr Index 0 1 2 3 4 5 6 7 8 9 A B C D E F AbsThr Level (V) Disable 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 Table 26: Delta Threshold Settings DelThr DelThr Level (V) Index 0 Disable 1 0.25 2 0.50 3 0.75 4 1.00 5 1.25 6 1.50 7 1.75 8 2.00 9 2.25 A 2.50 B 2.75 C 3.00 D 3.25 E 3.50 F 3.75
MinSamples MinSamples[2:0] is a Bemf sampling delay time expressed in number of PWM cycles, for more information please refer to the white paper "Robust Motion Control with AMIS-3062x Stepper Motor Drivers".
Table 27: Back emf Sample Delay Time Index 0 1 2 3 4 5 6 7 MinSamples[2:0] 000 001 010 011 100 101 110 111 tDELAY (s) PWMfreq = 0 87 130 174 217 261 304 348 391 PWMfreq = 1 43 65 87 109 130 152 174 196
FS2StallEn If AbsThr or DelThr <>0 (i.e. motion detection is enabled), then stall detection will be activated AFTER the acceleration ramp + an additional number of full-steps, according to the following table:
Table 28: Activation Delay of Motion Detection Index 0 1 2 3 4 5 6 7 FS2StallEn[2:0] 000 001 010 011 100 101 110 111 Delay (Full Steps) 0 1 2 3 4 5 6 7
For more information please refer to the white paper "Robust Motion Control with AMIS-3062x Stepper Motor Drivers". DC100StEn When a motor with large back - e.m.f. is operated at high velocity and low supply voltage, then the PWM duty cycle can be as high as 100 percent. This indicates that the supply is too low to generate the required torque and might also result in erroneously triggering the stall detection. The bit "DC100StEn" (Bit 1 in Data 7 of SetStallParam) enables the function where stall detection is switched off when PWM duty cycle equals 100 percent. For more information the white paper "Robust Motion Control with AMIS-3062x Stepper Motor Drivers". Motion Qualification Mode This mode is useful to debug motion parameters and to verify the stability of stepper motor systems. The motion qualification mode is entered by means of the I2C command TestBemf. The SWI pin will be converted into an analog output on which the Bemf integrator output can be measured. Once activated, it can only be stopped after a POR. During the back emf observation, reading of the SWI state is internally forbidden. More information is available in the white paper "Robust Motion Control with AMIS-3062x Stepper Motor Drivers".
Rev. 4 | Page 36 of 56 | www.onsemi.com
AMIS-30624
15.0 I2C Bus Description
15.1 General Description AMIS-30624 uses a simple bi-directional 2-wire bus for efficient inter-ic control. This bus is called the Inter IC or I C-bus. Features include: * Only two bus lines are required; a serial data line (SDA) and a serial clock line (SCK). * Each device connected to the bus is software addressable by a unique address and simple master/slave relationships exists at all times; master can operate as master-transmitter or as master receiver. * Serial, 8-bit oriented, bi-directional data transfers can be made up to 400 kbit/s. * On-chip filtering rejects spikes on the bus data line to preserve data integrity. * No need to design bus interfaces because I2C-bus interface is already integrated on-chip. * IC's can be added to or removed from a system without affecting any other circuits on the bus. 15.2 Concept The I2C-bus consists of two wires, serial data (SDA) and serial clock (SCK), carrying information between the devices connected on the bus. Each device connected to the bus is recognized by a unique address and operates as either a transmitter or receiver, depending on the function of the device. AMIS-30624 can both receive and transmit data. In addition to transmitters and receivers, devices can also be considered as masters or slaves when performing data transfers. AMIS-30624 is a slave device. See Table 30.
Table 29: Definition of I C -bus Terminology Term Description Transmitter The device which sends data on the bus Receiver The device which receives data from the bus Master The device which initiates a transfer, generates clock signals and terminates a transfer Slave The devices addressed by a master Synchronization Procedure to synchronizer the clock signals of two or more devices
2
2
Microcontroller
Motordriver_2 AMIS-30624
Motordriver_4 AMIS-30624
SDA SCL
Motordriver_1 AMIS-30624
Motordriver_3 AMIS-30624
PC20070217.1
Figure 23: Example of an I2C-bus Configuration Using One Microcontroller and Four Slaves
2 Figure 23 highlights the master-slave and receiver-transmitter relationships to be found on the I C-bus. It should be noted that these relationships are not permanent but only depend on the direction of data transfer at that time. The transfer of data would proceed as follows: 1) Suppose the microcontroller wants to send information to motordriver_1:
* Microcontroller (master) addresses motordriver_1 (slave) * Microcontroller (master-transmitter) sends data to motordriver_1 (slave-receiver) * Microcontroller terminates the transfer
Rev. 4 | Page 37 of 56 | www.onsemi.com
AMIS-30624
2) If the microcontroller wants to receive information from motordriver_2: * Microcontroller (master) addresses motordriver_2 (slave) * Microcontroller (master-receiver) receives data from motordriver_2 (slave-transmitter) * Microcontroller terminates the transfer Even in this case the master generates the timing and terminates the transfer. 2 Generation of the signals on the I C-bus is always the responsibility of the master device. It generates its own clock signal when transferring data on the bus. Bus clock signals from a master can only be altered when they are stretched by a slow slave device holding-down the clock line. 15.3 General Characteristics
+5 V Rp Serial Data Line Serial Clock Line SCK 2
Clock IN Clock OUT Data IN Data OUT
Rp
SDA 1
Clock IN Clock OUT
SCL
SDA
Data IN Data OUT
AMIS-30624
MASTER
PC20060925.7
Figure 24: Connection of a Device to the I2C-bus
Both SDA and SCK are bi-directional lines connected to a positive supply voltage via a pull-up resistor (see Figure 24). When the bus is free both lines are HIGH. The output stages of the devices connected to the bus must have an open drain to perform the wired-AND function. Data on the I2C-bus can be transferred up to 400kbits/s in fast mode. The number of interfaces connected to the bus is dependent on the maximum bus capacitance limit (See CB in Table 6) and the available number of addresses. 15.4 Bit Transfer The levels for logic `0' (LOW) and `1' (HIGH) are not fixed in the I2C standard but dependent on the used VDD level. Using AMIS-30624, the levels are specified in Table 5. One clock pulse is generated for each data bit transferred.
Rev. 4 | Page 38 of 56 | www.onsemi.com
AMIS-30624
15.4.1. Data Validity The data on the SDA line must be stable during the HIGH period of the clock. The HIGH or LOW state of the data line can only change when the clock signal on the SCL line is LOW (See Figure 25).
SDA
SCK
Data line stable -> Data valid
Change of data allowed
2
PC20070217.2
Figure 25: Bit Transfer on the I C-bus
15.4.2. START and STOP Conditions Within the procedure of the I2C-bus, unique situations arise, which are defined as START (S) and STOP (P) conditions (See Figure 26). A HIGH to LOW transition on the SDA line while SCK is HIGH is one such unique case. This situation indicates a START condition. LOW to HIGH transition on the SDA line while SCK is HIGH defines a STOP condition. START and STOP conditions are always generated by the master. The bus is considered to be busy after the START condition. The bus is considered to be free again a certain time after the STOP condition. The bus free situation is specified as tBUF in Table 6. The bus stays busy if a repeated START (Sr) is generated instead of a STOP condition. In this respect, the START (S) and repeated START (Sr) conditions are functionally identical (See Figure 27). The symbol S will be used to represent START and repeated START, unless otherwise noted.
START SDA
STOP
SCK
PC20070217.3
START condition
STOP condition
Figure 26: START and STOP Conditions
Rev. 4 | Page 39 of 56 | www.onsemi.com
AMIS-30624
15.5 Transferring Data 15.5.1. Byte Format Every byte put on the SDA line must be 8-bits long. The number of bytes that can be transmitted per transfer to AMIS-30624 is restricted to eight. Each byte has to be followed by an acknowledge bit. Data is transferred with the most significant bit (MSB) first (See Figure 27). If a slave can't receive or transmit another complete byte of data, it can hold the clock line SCK LOW to force the master into a wait state. Data transfer then continues when the slave is ready for another byte of data and releases clock line SCK.
START SDA STOP
MSB Acknowledgement signal from slave SCK
Clock line held low by slave
1 START condition
2
7
8
9
1
2
3-8
9 ACK STOP condition
Aknowledge related clock puse from master
PC20070217.4
Figure 27: Data Transfer on the I2C-bus
15.5.2. Acknowledge Data transfer with acknowledge is obligatory. The acknowledge-related clock pulse is generated by the master. The transmitter releases the SDA line (HIGH) during the acknowledge clock pulse. The receiver must pull down the SDA line during the acknowledge clock pulse so that it remains stable LOW during the HIGH period of this clock pulse (see Figure 28). Of course, set-up and hold times must also taken into account (see Table 6). When AMIS-30624 doesn't acknowledge the slave address, the data line will be left HIGH. The master can than generate either a STOP condition to abort the transfer, or a repeated START condition to start a new transfer. If AMIS-30624 as slave-receiver does acknowledge the slave address but later in the transfer cannot receive any more data bytes, this is indicated by generating a not-acknowledge on the first byte to follow. The master generates than a STOP or a repeated START condition. If a master-receiver is involved in the transfer, it must signal the end of data to the slave-transmitter by not generating an acknowledge on the last byte that was clocked out of the slave. AMIS-30624 as slave-transmitter shall release the data line to allow the master to generate STOP or repeated START condition.
START SDA by master transmitter MSB SDA by slave receiver Not acknowledged Master releases the Data line
SCK from master 1 2
Acknowledged 8 9
Slave pulls data line low if Acknowledged
START condition
Aknowledge related clock puse from master
PC20070217.5
Figure 28: Acknowledge on the I2C-bus
Rev. 4 | Page 40 of 56 | www.onsemi.com
AMIS-30624
15.5.3. Clock Generation The master generates the clock on the SCK line to transfer messages on the I2C-bus. Data is only valid during the HIGH period of the clock. 15.6 Data Formats with 7-bit Addresses Data transfers follow the format shown in Figure 29. After the START condition (S), a slave address is sent. This address is 7-bit long followed by an eighth bit which is a data direction bit (R/W) - a `zero' indicates a transmission (WRITE), a `one' indicates a request for data (READ). A data transfer is always terminated by a STOP condition (P) generated by the master.
START SDA
PC20070217.6
STOP
SCK 1-7 8 9 1-7 8 9 1-7 8 9
START condition
ADDRESS
R/W
ACK
DATA
ACK
DATA
ACK
STOP condition
Figure 29: A Complete Data Transfer
However, if a master still wishes to communicate on the bus, it can generate a repeated START (Sr) and address another slave without first generating a STOP condition. Various combinations of read/write formats are then possible within such a transfer. 15.6.1. Data Transfer Formats 15.6.1.1 Writing Data to AMIS-30624 When writing to AMIS-30624, the master-transmitter transmits to slave-receiver and the transfer direction is not changed. A complete transmission consists of: * * * * * Start condition The slave address (7-bit) Read/Write bit (`0' = write) Acknowledge bit Any further data bytes are followed by an acknowledge bit. The acknowledge bit is used to signal a correct reception of the data to the transmitter. In this case the AMIS-30624 pulls the SDA line to `0'. The AMIS-30624 reads the incoming data at SDA on every rising edge of the SCK signal * Stop condition to finish the transmission *
S Slave Address
R/W
A
Data
A
Data
A
P
"0" = WRITE Master to AMIS-30624 AMIS-30624 to Master
N bytes + Acknowledge S = Start condition P = Stop condition A = Acknowledge (SDA = LOW) A = No Acknowledge (SDA = HIGH)
PC20070219.3
Figure 30: Master Writing Data to AMIS-30624
Some commands for the AMIS-30624 are supporting eight bytes of data, other commands are transmitting two bytes of data. See Table 30.
Rev. 4 | Page 41 of 56 | www.onsemi.com
AMIS-30624
15.6.1.2 Reading Data to AMIS-30624 When reading data from AMIS-30624 two transmissions are needed: 1) The first transmission consists of two bytes of data: * The first byte contains the slave address and the write bit. * The second byte contains the address of an internal register in the AMIS-30624. This internal register address is stored in the circuit RAM.
S Slave Address
R/W
A
Internal Address
A
P
"0" = WRITE
PC20070219.5
Figure 31: Master Reading Data from AMIS-30624: First Transmission is Addressing
2) The second transmission consists of the slave address and the read bit. Then the master can read the data bits on the SDA line on every rising edge of signal SCK. After each byte of data the master has to acknowledge correct data reception by pulling SDA LOW. The last byte is not acknowledged by the master and therefore the slave knows the end of transmission.
S Slave Address
R/W
A
Data
A
Data
A
P
"0" = WRITE Master to AMIS-30624 AMIS-30624 to Master
N bytes + Acknowledge S = Start condition P = Stop condition A = Acknowledge (SDA = LOW) A = No Acknowledge (SDA = HIGH)
PC20070219.3
Figure 32: Master Reading Data from AMIS-30624: Second Transmission is Reading Data
Notes: (1) (2) (3) Each byte is followed by an acknowledgment bit as indicated by the A or in the sequence. I2C-bus compatible devices must reset their bus logic on receipt of a START condition such that they all anticipate the sending of a slave address, even if these START conditions are not positioned according to the proper format. A START condition immediately followed by a STOP condition (void message) is an illegal format.
15.7 7-bit Addressing The addressing procedure for the I2C-bus is such that the first byte after the START condition usually determines which slave will be selected by the master. The exception is the general call address which can call all devices. When this address is used all devices should respond with an acknowledge. The second byte of the general call address then defines the action to be taken. 15.7.1. Definition of Bits in the First Byte The first seven bits of the first byte make up the slave address. The eighth bit is the least significant bit (LSB). It determines the direction of the message. If the LSB is a "zero" it means that the master will write information to a selected slave. A "one" in this position means that the master will read information from the slave. When an address is sent, each device in a system compares the first seven bits after the START condition with its address. If they match, the device considers itself addressed by the master as a slave-receiver or slave-transmitter, depending on the R/ W bit.
MSB LSB R/W
SLAVE ADDRESS
PC20070219.2
Figure 33: First Byte after START Procedure
Rev. 4 | Page 42 of 56 | www.onsemi.com
AMIS-30624
AMIS-30624 is provided with a physical address in order to discriminate this circuit from other circuits on the I2C bus. This address is coded on seven bits (two bits being internally hardwired to `1'), yielding the theoretical possibility of 32 different circuits on the same bus. It is a combination of four OTP memory bits (OTP Memory Structure) and of the externally hardwired address bits (pin HW). HW must either be connected to ground or to Vbat. When HW is not connected and is left floating, correct functionality of the positioner is not guaranteed. The motor will be driven to the programmed secure position (See Hardwired Address - OPEN).
MSB 1 1 LSB PA3 PA2 PA1 PA0 HW R/W
PC20070219.3
OTP memory
Hardwired Address Bit
Figure 34: First Byte after START Procedure
15.7.2. General Call Address
The AMIS-30624 supports also a "general call" address "000 0000", which can address all devices. When this address is used all devices should respond with an acknowledge. The second byte of the general call address then defines the action to be taken.
Rev. 4 | Page 43 of 56 | www.onsemi.com
AMIS-30624
16.0 I2C Application Commands
16.1 Introduction
Communications between the AMIS-30624 and a 2-wire serial bus interface master takes place via a large set of commands. Reading commands are used to: * Get actual status information, e.g. error flags * Get actual position of the stepper motor * Verify the right programming and configuration of the AMIS-30624 Writing commands are used to: * Program the OTP memory * Configure the positioner with motion parameters (max/min speed, acceleration, stepping mode, etc.) * Provide target positions to the Stepper motor The I2C-bus master will have to use commands to manage the different application tasks the AMIS-30624 can feature. The commands summary is given in Table 30.
16.2 Commands Table
Table 30: I C Commands with Corresponding ROM Pointer
Command Mnemonic GetFullStatus1 GetFullStatus2 GetOTPParam GotoSecurePosition HardStop ResetPosition ResetToDefault SetDualPosition SetMotorParam SetOTP SetPosition SetStallParam SoftStop Runvelocity TestBemf Function Command Byte Binary Hexadecimal "1000 0001" 0x81 "1111 1100" 0xFC "1000 0010" 0x82 "1000 0100" 0x84 "1000 0101" 0x85 "1000 0110" 0x86 "1000 0111" 0x87 "1000 1000" 0x88 "1000 1001" 0x89 "1001 0000" 0x90 "1000 1011" 0x8B "1001 0110" 0x96 "1000 1111" 0x8F "1001 0111" 0x97 "1001 1111" 0x9F
2
Returns complete status of the chip Returns actual, target and secure position Returns OTP parameter Drives motor to secure position Immediate full stop Sets actual position to zero Overwrites the chip RAM with OTP contents Drives the motor to two different positions with different speed Sets motor parameter Zaps the OTP memory Programs a target and secure position Sets stall parameters Motor stopping with deceleration phase Drives motor continuously Outputs Bemf voltage on pin SWI
These commands are described hereafter, with their corresponding I2C frames. Refer to Data Transfer Formats for more details. A color coding is used to distinguish between master and slave parts within the frames. An example is shown below. Light Blue : Master data
Byte Content Bit 7 1 1 GetFullStatus1 Response Frame Structure Bit 6 Bit 5 Bit 4 Bit 3 1 OTP3 OTP2 OTP1 1 1 Irun[3:0] OTP3 OTP2
0 1 2
Address Address Data 1
Bit 2 OTP0
Bit 1 HW
Bit 0 0 HW
OTP1 OTP0 Ihold[3:0]
White: Slave response
Figure 35: Color Code Used in the Definition of I2C Frames
Rev. 4 | Page 44 of 56 | www.onsemi.com
AMIS-30624
16.3 Application Commands 16.3.1. GetFullStatus1
This command is provided to the circuit by the master to get a complete status of the circuit and of the stepper motor. Refer to Table 18 and Table 19 to see the meaning of the parameters sent back to the I2C master.
Note: A GetFullStatus1 command will attempt to reset flags , , , , , , , , and . GetFullStatus1 corresponds to the following I2C command frame:
Byte Content GetFullStatus1 Command Frame Structure Bit 6 Bit 5 Bit 4 Bit 3 1 OTP3 OTP2 OTP1 0 0 0 0 GetFullStatus1 Response Frame Structure Bit 6 Bit 5 Bit 4 Bit 3 1 OTP3 OTP2 OTP1 1 1 Irun[3:0] Vmax[3:0] OTP3 OTP2
0 1
Address Command
Bit 7 1 1
Bit 2 OTP0 0
Bit 1 HW 0
Bit 0 0 1
Byte
Content
0 1 2 3 4 5 6 7 8
Address Address Data 1 Data 2 Data 3 Data 4 Data 5 Data 6 Data 7
Bit 7 1 1
Bit 2 OTP0
Bit 1 HW
Bit 0 1
AccShape VddReset
StepMode[1:0]
StepLoss
ElDef
1
Motion[2:0] 1 1 AbsThr[3:0]
Shaft UV2 ESW 1
TSD OVC1 1
OTP1 OTP0 HW Ihold[3:0] Vmin[3:0] Acc[3:0] Tinfo[1:0] TW OVC2 Stall CPFail 1 1 1 DelThr[3:0]
Where: OTP(n) HW Irun[3:0] Ihold[3:0] Vmax[3:0] Vmin[3:0] AccShape StepMode[1:0] Shaft Acc[3:0] VddReset StepLoss ElDef UV2 TSD TW Tinfo[1:0] Motion[2:0] ESW OVC1 OVC2 Stall CPFail AbsThr[3:0] DelThr[3:0]
OTP address bits PA[3:0] Hardwired address bit Operating current in the motor coil Standstill current in the motor coil Maximum velocity Minimum velocity Enables motion without acceleration Step mode definition Direction of movement Acceleration form minimum to maximum velocity Reset of digital supply Step loss occurred Electrical defect Battery under voltage detected Thermal shutdown Thermal warning Temperature Info Motion status External switch status Over current in X-coil detected Over current in Y-coil detected Stall detected Charge pump failure Stall detection absolute threshold Stall detection delta threshold
Rev. 4 | Page 45 of 56 | www.onsemi.com
AMIS-30624
16.3.2. GetFullStatus2
This command is provided to the circuit by the master to get the actual, target and secure position of the stepper motor. Both the actual and target position are returned in signed two's complement 16-bit format. Secure position is coded in 10-bit format. According to the programmed stepping mode the LSBs of ActPos[15:0] and TagPos[15:0] may have no meaning and should be assumed to be `0'. This command also gives additional information concerning stall detection. Refer to Table 18 and Table 19 to see the meaning of the parameters sent back to the I2C master. GetFullStatus2 corresponds to the following I2C command frame:
GetFullStatus2 Command Frame Structure Bit 6 Bit 5 Bit 4 Bit 3 1 OTP3 OTP2 OTP1 1 1 1 1
Byte
Content
0 1
Address Command
Bit 7 1 1
Bit 2 OTP0 1
Bit 1 HW 0
Bit 0 0 0
Byte
Content
0 1 2 3 4 5 6 7 8
Address Address Data 1 Data 2 Data 3 Data 4 Data 5 Data 6 Data 7
GetFullStatus2 Response Frame Structure Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 1 1 OTP3 OTP2 OTP1 OTP0 HW 1 1 1 1 OTP3 OTP2 OTP1 OTP0 HW ActPos[15:8] ActPos[7:0] TagPos[15:8] TagPos[7:0] SecPos[7:0] FS2StallEn[2:0] 1 DC100 SecPos[10:8] DelStallLo DelStallHi DC100StEn AbsStall MinSamples[2:0] PWMJEn
Where: OTP(n) HW ActPos[15:0] TagPos[15:0] SecPos[10:0] FS2StallEn[2:0] DC100 AbsStall DelStallLo DelStallHi: MinSamples[2:0] DC100StEn PWMJEn
OTP address bits PA[3:0] Hardwired address bit Actual position Target position Secure position Number of full steps after stall detection is enabled Flag indicating PWM is at 100 percent duty cycle Stall detected because the absolute threshold is not reached Stall detected because the delta threshold is under crossed Stall detected because the delta threshold is crossed Back-emf sampling delay time Enables the switch off of stall detection when DC100 = 1 PWM jitter enable
Rev. 4 | Page 46 of 56 | www.onsemi.com
AMIS-30624
16.3.3. GetOTPParam
This command is provided to the circuit by the I2C master to read the content of the OTP memory. More information can be found in OTP Memory Structure.
GetOTPParam corresponds to the following I C command frame:
Byte Content GetOTPParam Command Frame Structure Bit 6 Bit 5 Bit 4 Bit 3 1 OTP3 OTP2 OTP1 0 0 0 0 GetOTPParam Response Frame Structure Bit 6 Bit 5 Bit 4 Bit 3 1 OTP3 OTP2 OTP1 OTP byte @0x00 OTP byte @0x01 OTP byte @0x02 OTP byte @0x03 OTP byte @0x04 OTP byte @0x05 OTP byte @0x06 OTP byte @0x07
2
0 1
Address Command
Bit 7 1 1
Bit 2 OTP0 0
Bit 1 HW 1
Bit 0 0 0
Byte
Content
0 1 2 3 4 5 6 7 8
Address OTP byte 0 OTP byte 1 OTP byte 2 OTP byte 3 OTP byte 4 OTP byte 5 OTP byte 6 OTP byte 7
Bit 7 1
Bit 2 OTP0
Bit 1 HW
Bit 0 1
16.3.4. GotoSecurePosition
This command is provided by the I2C master to one or all the stepper motors to move to the secure position SecPos[10:0]. See the priority encoder description for more details. The priority encoder table also acknowledges the cases where a GotoSecurePosition command will be ignored.
GotoSecurePosition corresponds to the following I2C command frame:
Byte Content GotoSecurePosition Command Frame Structure Bit 6 Bit 5 Bit 4 Bit 3 1 OTP3 OTP2 OTP1 0 0 0 0
0 1
Address Command
Bit 7 1 1
Bit 2 OTP0 1
Bit 1 HW 0
Bit 0 0 0
16.3.5. HardStop
This command will be internally triggered when an electrical problem is detected in one or both coils, leading to shutdown mode. If this occurs while the motor is moving, the flag is raised to allow warning of the I2C master at the next GetStatus1 command that steps may have been lost. Once the motor is stopped, ActPos register is copied into TagPos register to ensure keeping the stop position. The I2C master for some safety reasons can also issue a HardStop command.
HardStop corresponds to the following I2C command frame:
Byte Content HardStop Command Frame Structure Bit 6 Bit 5 Bit 4 Bit 3 1 OTP3 OTP2 OTP1 0 0 0 0
0 1
Address Command
Bit 7 1 1
Bit 2 OTP0 1
Bit 1 HW 0
Bit 0 0 1
16.3.6. ResetPosition
This command is provided to the circuit by the I2C master to reset ActPos and TagPos registers to zero. This can be helpful to prepare for instance a relative positioning.
Rev. 4 | Page 47 of 56 | www.onsemi.com
AMIS-30624
ResetPosition corresponds to the following I2C command frame:
Byte Content ResetPosition Command Frame Structure Bit 6 Bit 5 Bit 4 Bit 3 1 OTP3 OTP2 OTP1 0 0 0 0
0 1
Address Command
Bit 7 1 1
Bit 2 OTP0 1
Bit 1 HW 1
Bit 0 0 0
16.3.7. ResetToDefault
This command is provided to the circuit by the I2C master in order to reset the whole slave node into the initial state. ResetToDefault will, for instance, overwrite the RAM with the reset state of the registers parameters (see Table 18). This is another way for the I2C master to initialize a slave node in case of emergency, or simply to refresh the RAM content.
Note: ActPos and TagPos are not modified by a ResetToDefault command. Important: Care should be taken not to send a ResetToDefault command while a motion is ongoing, since this could modify the motion parameters in a way forbidden by the position controller. ResetToDefault corresponds to the following I2C command frame:
Byte Content ResetToDefault Command Frame Structure Bit 6 Bit 5 Bit 4 Bit 3 1 OTP3 OTP2 OTP1 0 0 0 0
0 1
Address Command
Bit 7 1 1
Bit 2 OTP0 1
Bit 1 HW 1
Bit 0 0 1
16.3.8. RunVelocity
This command is provided to the circuit by the I2C master in order to put the motor in continuous motion state.
RunVelocity corresponds to the following I2C command frame:
RunVelocity Command Frame Structure Bit 6 Bit 5 Bit 4 Bit 3 1 OTP3 OTP2 OTP1 0 0 1 0
Byte
Content
0 1
Address Command
Bit 7 1 1
Bit 2 OTP0 1
Bit 1 HW 1
Bit 0 0 1
16.3.9. SetDualPosition
This command is provided to the circuit by the I2C master in order to perform a positioning of the motor using two different velocities. See Section Dual Positioning.
Note1: This sequence cannot be interrupted by another positioning command. Important: If for some reason ActPos equals Pos1[15:0] at the moment the SetDualPosition command is issued, the circuit will enter in deadlock state. Therefore, the application should check the actual position by a GetFullStatus2 command prior to starting a dual positioning. Another solution may consist of programming a value out of the stepper motor range for Pos1[15:0]. For the same reason Pos2[15:0] should not be equal to Pos1[15:0]. SetDualPosition corresponds to the following I2C command frame:
Rev. 4 | Page 48 of 56 | www.onsemi.com
AMIS-30624
Byte Content Bit 7 1 1 1 1 SetDualPosition Command Frame Structure Bit 6 Bit 5 Bit 4 Bit 3 1 OTP3 OTP2 OTP1 0 0 0 1 1 1 1 1 1 1 1 1 Vmax[3:0] Pos1[15:8] Pos1[7:0] Pos2[15:8] Pos2[7:0] Bit 2 Bit 1 OTP0 HW 0 0 1 1 1 1 Vmin[3:0] Bit 0 0 0 1 1
0 1 2 3 4 5 6 7 8
Address Command Data 1 Data 2 Data 3 Data 4 Data 5 Data 6 Data 7
Where: Vmax[3:0] Vmin[3:0] Pos1[15:0] Pos2[15:0]
Max. velocity for first motion Min. velocity for first motion and velocity for the second motion First position to be reached during the first motion Relative position of the second motion
16.3.10. SetStallParam
This command sets the motion detection parameters and the related stepper motor parameters, such as the minimum and maximum velocity, the run- and hold current, acceleration and step-mode. See Motion Detection for the meaning of these parameters.
SetStallParam corresponds to the following I2C command frame:
Byte Content SetStallParam Command Frame Structure Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 1 1 OTP3 OTP2 OTP1 OTP0 HW 1 0 0 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Irun[3:0] Ihold[3:0] Vmax[3:0] Vmin[3:0] MinSamples[2:0] Shaft Acc[3:0] AbsThr[3:0] DelThr[3:0] FS2StallEn[2:0] AccShape StepMode[1:0] DC100StEn
0 1 2 3 4 5 6 7 8
Address Command Data 1 Data 2 Data 3 Data 4 Data 5 Data 6 Data 7
Bit 0 0 0 1 1
PWMJEn
16.3.11. SetMotorParam
This command is provided to the circuit by the I2C master to set the values for the stepper motor parameters (listed below) in RAM. Refer to Table 18 to see the meaning of the parameters sent by the I2C master.
Important: If a SetMotorParam occurs while a motion is ongoing, it will modify at once the motion parameters (see Position Controller). Therefore the application should not change parameters other than Vmax and Vmin while a motion is running, otherwise correct positioning cannot be guaranteed. SetMotorParam corresponds to the following I2C command frame:
Byte Content SetMotorParam Command Frame Structure Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 1 OTP3 OTP2 OTP1 OTP0 HW 0 0 0 1 0 0 1 1 1 1 1 1 1 1 1 1 1 1 Irun[3:0] Ihold[3:0] Vmax[3:0] Vmin[3:0] SecPos[10:8] Shaft Acc[3:0] SecPos[7:0] 1 AccShape PWMfreq 1 StepMode[1:0]
0 1 2 3 4 5 6 7 8
Address Command Data 1 Data 2 Data 3 Data 4 Data 5 Data 6 Data 7
Bit 7 1 1 1 1
Bit 0 0 1 1 1
1
PWMJEn
Rev. 4 | Page 49 of 56 | www.onsemi.com
AMIS-30624
16.3.12. SetOTPParam
This command is provided to the circuit by the I2C master to program and zap the OTP data D[7:0] in OTP address OTPA[2:0].
Important: This command must be sent under a specific Vbb voltage value. See parameter VbbOTP in Table 5. This is a mandatory condition to ensure reliable zapping. SetOTPParam corresponds to the following I2C command frame:
Byte Content SetOTPParam Command Frame Structure Bit 6 Bit 5 Bit 4 Bit 3 1 OTP3 OTP2 OTP1 0 0 1 0 1 1 1 1 1 1 1 1 1 1 1 1 D[7:0]
0 1 2 3 4 5
Address Command Data 1 Data 2 Data 3 Data 4
Bit 7 1 1 1 1 1
Bit 2 OTP0 0 1 1
Bit 1 HW 0 1 1 OTPA[2:0]
Bit 0 0 0 1 1
Where: OTPA[2:0]: OTP address D[7:0]: Corresponding OTP data
16.3.13. SetPosition
This command is provided to the circuit by the I2C master to drive the motor to a given absolute position. See Positioning for more details. The priority encoder table (see Priority Encoder) acknowledges the cases where a SetPosition command will be ignored.
SetPosition corresponds to the following I2C command frame:
Byte Content SetPosition Command Frame Structure Bit 6 Bit 5 Bit 4 Bit 3 1 OTP3 OTP2 OTP1 0 0 0 1 1 1 1 1 1 1 1 1 Pos[15:8] Pos[7:0]
0 1 2 3 4 5
Address Command Data 1 Data 2 Data 3 Data 4
Bit 7 1 1 1 1
Bit 2 OTP0 0 1 1
Bit 1 HW 1 1 1
Bit 0 0 1 1 1
Where: Pos [15:0] Signed 16-bit position set-point for motor.
16.3.14. SoftStop
This command will be internally triggered when the chip temperature rises above the thermal shutdown threshold (see Table 5 and Section 14.2.5). It provokes an immediate deceleration to Vmin (see Minimum Velocity) followed by a stop, regardless of the position reached. Once the motor is stopped, TagPos register is overwritten with value in ActPos register to ensure keeping the stop position. The I2C Master for some safety reasons can also issue a SoftStop command.
SoftStop corresponds to the following I2C command frame:
Byte Content SoftStop Command Frame Structure Bit 6 Bit 5 Bit 4 Bit 3 1 OTP3 OTP2 OTP1 0 0 0 1
0 1
Address Command
Bit 7 1 1
Bit 2 OTP0 1
Bit 1 HW 1
Bit 0 0 1
16.3.15. TestBemf
This command is provided to the circuit by the I2C master in order to output the Bemf integrator output to the SWI output of the chip. Once activated, it can be stopped only after POR. During the Bemf observation, reading of the SWI state is internally forbidden.
Rev. 4 | Page 50 of 56 | www.onsemi.com
AMIS-30624
TestBemf corresponds to the following I2C command frame:
Byte Content TestBemf Command Frame Structure Bit 6 Bit 5 Bit 4 Bit 3 1 OTP3 OTP2 OTP1 0 0 1 1
0 1
Address Command
Bit 7 1 1
Bit 2 OTP0 1
Bit 1 HW 1
Bit 0 0 1
Rev. 4 | Page 51 of 56 | www.onsemi.com
AMIS-30624
17.0 Resistance to Electrical and Electromagnetic Disturbances
17.1 Electrostatic Discharges
Table 31: Absolute Maximum Ratings Vesd
Notes: (1)
(1)
Parameter Electrostatic discharge voltage on all pins
Min. -2
Max. +2
Unit kV
Human body model (100pF via 1.5 k, according to JEDEC EIA-JESD22-A114-B.)
17.2 Electrical Transient Conduction Along Supply Lines
Test pulses are applied to the power supply wires of the equipment implementing the AMIS-30624 (see application schematic), according to ISO 7637-1 document. Operating Classes are defined in ISO 7637-2.
Table 32: Test Pulses and Test Levels According to ISO 7637-1 Pulse Amplitude #1 -100V #2a #3a #3b #5b (load dump) +100V -150V (from +13.5V) +100V (from +13.5V) +21.5V (from +13.5V)
Rise Time 1s 1s Pulse Duration 2ms Rs 10 Operating Class C
50s 100ns (burst) 100ns (burst) 400ms
2 50 50
1
B A A C
5ns 5ns
10ms
17.3 EMC
Bulk current injection (BCI), according to ISO 11452-4. Operating Classes are defined in ISO 7637-2.
Table 33: Bulk Current Injection Operating Classes Current 60mA envelope 100mA envelope 200mA envelope
Operating Class
A B C
17.4 Power Supply Micro-interruptions
According to ISO 16750-2
Table 34: Immunity to Power Supply Micro-interruptions Test 10s micro-interruptions 100s micro-interruptions 5ms micro-interruptions 50ms micro-interruptions 300ms micro-interruptions
Operating Class
A B B C C
Rev. 4 | Page 52 of 56 | www.onsemi.com
AMIS-30624
18.0 Package Outline
Figure 36: SOIC-20: Plastic Small Outline; 20 leads; Body Width 300mil. AMIS reference: SOIC300 20 300G
Rev. 4 | Page 53 of 56 | www.onsemi.com
AMIS-30624
Dimensions: Dim Min A 0.8 A1 0 A2 0.576 A3 b 0.25 C 0.24 D D1 E E1 e J 5.37 K 5.37 L 0.35 P R 2.185
Nom
0.02 0.615 0.203 0.3 0.42 7 6.75 7 6.75 0.65 5.47 5.47 0.4 45
Max 0.9 0.05 0.654
0.35 0.6
5.57 5.57 0.45 2.385
Unit mm mm mm mm mm mm mm mm mm mm mm mm mm mm Degree mm
Notes
2) Dimensions apply to plated terminal and are measured between 0.2 and 0.25 mm from terminal tip. 3) The pin #1 indication must be placed on the top surface of the package by using indentation mark or other feature of package body. 4) Exact shape and size of this feature is optional 5) Applied for exposed pad and terminals. Exclude embedding part of exposed pad from measuring. 6) Applied only to terminals 7) Exact shape of each corner is optional
7x7 NQFP
Figure 37: NQFP-32: No lead Quad Flat Pack; 32 pins; body size 7 x 7 mm. AMIS reference: NQFP-32
Rev. 4 | Page 54 of 56 | www.onsemi.com
AMIS-30624
19.0 Soldering
19.1 Introduction to Soldering Surface Mount Packages
This text gives a very brief insight to a complex technology. A more in-depth account of soldering ICs can be found in the ON Semiconductor "Data Handbook IC26; Integrated Circuit Packages" (document order number 9398 652 90011). There is no soldering method that is ideal for all surface mount IC packages. Wave soldering is not always suitable for surface mount ICs, or for printedcircuit boards with high population densities. In these situations re-flow soldering is often used.
19.2 Re-flow Soldering
Re-flow soldering requires solder paste (a suspension of fine solder particles, flux and binding agent) to be applied to the PCB by screen printing, stencilling or pressure-syringe dispensing before package placement. Several methods exist for reflowing; for example, infrared/convection heating in a conveyor type oven. Throughput times (preheating, soldering and cooling) vary between 100 and 200 seconds depending on the heating method. Typical reflow peak temperatures range from 215 to 260C. The top-surface temperature of the packages should preferably be kept below 230C.
19.3 Wave Soldering
Conventional single wave soldering is not recommended for surface mount devices (SMDs) or PCBs with a high component density, as solder bridging and non-wetting can present major problems. To overcome these problems, the double-wave soldering method was specifically developed. If wave soldering is used the following conditions must be observed for optimal results: * Use a double-wave soldering method comprising a turbulent wave with high upward pressure followed by a smooth laminar wave. * For packages with leads on two sides and a pitch (e): o Larger than or equal to 1.27mm, the footprint longitudinal axis is preferred to be parallel to the transport direction of the PCB; o Smaller than 1.27mm, the footprint longitudinal axis must be parallel to the transport direction of the PCB. The footprint must incorporate solder thieves at the downstream end. * For packages with leads on four sides, the footprint must be placed at a 45 angle to the transport direction of the PCB. The footprint must incorporate solder thieves downstream and at the side corners. During placement and before soldering, the package must be fixed with a droplet of adhesive. The adhesive can be applied by screen printing, pin transfer or syringe dispensing. The package can be soldered after the adhesive is cured. Typical dwell time is four seconds at 250C. A mildly-activated flux will eliminate the need for removal of corrosive residues in most applications.
19.4 Manual Soldering
Fix the component by first soldering two diagonally-opposite end leads. Use a low voltage (24V or less) soldering iron applied to the flat part of the lead. Contact time must be limited to 10 seconds at up to 300C. When using a dedicated tool, all other leads can be soldered in one operation within two to five seconds between 270 and 320C.
Table 35: Soldering Process
Package Soldering Method Wave Re-flow
(1)
BGA, SQFP HLQFP, HSQFP, HSOP, HTSSOP, SMS PLCC (3) , SO, SOJ LQFP, QFP, TQFP SSOP, TSSOP, VSO
Notes: (1) (2) (3) (4) (5)
Not suitable (2) Not suitable Suitable (3)(4) Not recommended (5) Not recommended
Suitable Suitable Suitable Suitable Suitable
All surface mount (SMD) packages are moisture sensitive. Depending upon the moisture content, the maximum temperature (with respect to time) and body size of the package, there is a risk that internal or external package cracks may occur due to vaporization of the moisture in them (the so called popcorn effect). For details, refer to the drypack information in the "Data Handbook IC26; Integrated Circuit Packages; Section: Packing Methods." These packages are not suitable for wave soldering as a solder joint between the printed-circuit board and heatsink (at bottom version) can not be achieved, and as solder may stick to the heatsink (on top version). If wave soldering is considered, then the package must be placed at a 45 angle to the solder wave direction. The package footprint must incorporate solder thieves downstream and at the side corners. Wave soldering is only suitable for LQFP, TQFP and QFP packages with a pitch (e) equal to or larger than 0.8mm; it is definitely not suitable for packages with a pitch (e) equal to or smaller than 0.65mm. Wave soldering is only suitable for SSOP and TSSOP packages with a pitch (e) equal to or larger than 0.65mm; it is definitely not suitable for packages with a pitch (e) equal to or smaller than 0.5mm.
Rev. 4 | Page 55 of 56 | www.onsemi.com
AMIS-30624
20.0 Revision History
Revision 1.0 2.1 3.0 3.1 4.0 Date July 16, 2002 th December 5 , 2005 February 21, 2007 March 23, 2007 June 17, 2008 Modifications First non-preliminary issue Complete review Public release 2 UpdateI C commands, adding links Move content into ON Semiconductor template; update OPN table
21.0 Company or Product Inquiries
For more information about ON Semiconductor's products or services visit our Web site at http://www.amis.com.
ON Semiconductor and are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. "Typical" parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including "Typicals" must be validated for each customer application by customer's technical experts. SCILLC does not convey any license under its patent rights nor the rights of others. SCILLC products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where personal injury or death may occur. Should Buyer purchase or use SCILLC products for any such unintended or unauthorized application, Buyer shall indemnify and hold SCILLC and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture of the part. SCILLC is an Equal Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner.
PUBLICATION ORDERING INFORMATION
LITERATURE FULFILLMENT: Literature Distribution Center for ON Semiconductor P.O. Box 5163, Denver, Colorado 80217 USA Phone: 303-675-2175 or 800-344-3860 Toll Free USA/Canada Fax: 303-675-2176 or 800-344-3867 Toll Free USA/Canada Email: orderlit@onsemi.com N. American Technical Support: 800-282-9855 Toll Free USA/Canada Europe, Middle East and Africa Technical Support: Phone: 421 33 790 2910 Japan Customer Focus Center Phone: 81-3-5773-3850
ON Semiconductor Website: www.onsemi.com Order Literature: http://www.onsemi.com/orderlit For additional information, please contact your local Sales Representative
Rev. 4 | Page 56 of 56 | www.onsemi.com


▲Up To Search▲   

 
Price & Availability of AMIS30624C6244G

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X